부하 시험기 1,200kWAptis
APS1200
부하 시험기 1,200kW
Aptis
APS1200
FCA VB 부가세 별도
€35,000
제조 연도
2026
상태
중고
(완전히 작동합니다)
위치
Pula 

기본 정보
가격 및 위치
FCA VB 부가세 별도
€35,000
- 임대:
- 가능합니다
- 위치:
- Pula, 크로아티아

전화하기
기술 세부 사항
치수 및 중량
총중량:
1,300 kg
총 길이:
1,800 mm
총 폭:
1,470 mm
총 높이:
2,170 mm
문서화 및 인증
CE 마킹
제안 세부 정보
- 광고 ID:
- A23348348
- 업데이트:
- 마지막 업데이트: 17.11.2026
설명
For sale or rent: Outdoor resistive load banks (2 units are available) with a rated capacity of 1200 kW at 400 V AC, three-phase with neutral, 50/60 Hz. The unit provides a purely resistive load (power factor 1) and is designed for continuous duty in a weatherproof enclosure, including operation outdoors in rain.
The load is built up from 11 switchable steps (25 + 25 + 50 + 50 + 50 + 100 + 100 + 200 + 200 + 200 + 200 kW), which allows any value from 25 kW to 1200 kW to be set in 25 kW increments. Step tolerance is ±5 %, overall load tolerance ±3 %.
The load bank can be operated locally from the control panel or remotely via Modbus. Each load step, fan supply and load confirmation can be controlled over Modbus RTU (RS485/RS232) or Modbus TCP (RJ45), and status, alarms and measured values are available for monitoring. This makes the unit suitable both for classic generator testing and for integration into SCADA, energy management or virtual power plant systems as a controllable load.
A built-in class 0.5 multifunction meter displays voltage, current, active power and frequency in real time. The control system is based on a Siemens PLC, with Schneider contactors and Miro fuses.
Typical applications:
• Load testing and commissioning of diesel and gas generator sets
Ijdpfxj Akvd Rj Aphetp
• Testing of UPS systems and other power sources
• Periodic loading of standby generators to prevent wet stacking
• Controllable load for grid balancing services (e.g. aFRR) and flexibility applications
Protection functions:
• Emergency stop with immediate unloading (fans keep running for cool-down)
• Overtemperature, overvoltage and insufficient airflow protection with automatic unloading and audible/visual alarm
• Fan interlock – load cannot be applied unless cooling fans are running
• Automatic fan phase-sequence correction
• Fuse short-circuit protection and enclosure earthing terminal
The load is built up from 11 switchable steps (25 + 25 + 50 + 50 + 50 + 100 + 100 + 200 + 200 + 200 + 200 kW), which allows any value from 25 kW to 1200 kW to be set in 25 kW increments. Step tolerance is ±5 %, overall load tolerance ±3 %.
The load bank can be operated locally from the control panel or remotely via Modbus. Each load step, fan supply and load confirmation can be controlled over Modbus RTU (RS485/RS232) or Modbus TCP (RJ45), and status, alarms and measured values are available for monitoring. This makes the unit suitable both for classic generator testing and for integration into SCADA, energy management or virtual power plant systems as a controllable load.
A built-in class 0.5 multifunction meter displays voltage, current, active power and frequency in real time. The control system is based on a Siemens PLC, with Schneider contactors and Miro fuses.
Typical applications:
• Load testing and commissioning of diesel and gas generator sets
Ijdpfxj Akvd Rj Aphetp
• Testing of UPS systems and other power sources
• Periodic loading of standby generators to prevent wet stacking
• Controllable load for grid balancing services (e.g. aFRR) and flexibility applications
Protection functions:
• Emergency stop with immediate unloading (fans keep running for cool-down)
• Overtemperature, overvoltage and insufficient airflow protection with automatic unloading and audible/visual alarm
• Fan interlock – load cannot be applied unless cooling fans are running
• Automatic fan phase-sequence correction
• Fuse short-circuit protection and enclosure earthing terminal