착유 기술 캐비닛용 모듈 캐리어Areva
Teleperm XS
착유 기술 캐비닛용 모듈 캐리어
Areva
Teleperm XS
VB 부가세 별도
€6,550
상태
신규
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
VB 부가세 별도
€6,550
- 위치:
- Dunkerstrasse 29, 46325 Borken/Burlo, DE
전화하기
제안 세부 정보
- 광고 ID:
- A16417386
- 참조 번호:
- 38434
- 업데이트:
- 마지막 업데이트: 28.08.2025
설명
Areva Teleperm XS Control Cabinet
Standard Construction
For the construction of Teleperm XS systems,
SC 9422 control cabinets (2200 x 900 x 400 mm deep), IP30 protection class, are typically used.
The cabinet is equipped with cable clamps with shielding bars.
The cabinet is designed for seismic loads.
Cable entry and power supply are generally from below.
In the standard cabinet, the subracks are mounted in the middle section.
To the left and right of these are areas for mounting cabinet connection elements and transceivers.
Terminal blocks are used to connect peripheral cables.
Other connection technologies, such as Maxi-Termi-Point, are also possible.
Field cables must be shielded with twisted pairs.
Buses are implemented using conventional cables within a cabinet and fiber optic cables outside the cabinet.
Teleperm XS is suitable for systems with both surface grounding and central grounding (CEP).
Subracks
Various subrack configurations are used depending on the application.
The basic version of the subrack has a continuous backplane bus and offers 21 slots.
If large signal volumes need to be recorded, expansion subracks can be connected.
Hfodpfxotzaxme Aatjn
Variants are also supported:
- Split racks with two smaller, independent computers
(10 slots each, each with its own fans and power supply)
- Mixed configurations such as the compact combination of a computer with the associated signal conditioning modules
SC 9422 Control Cabinet
with cross bracing
Double doors
Cabinet indicator light
Height × Width × Depth: 2200 × 900 × 400 mm
Protection class: IP30
Power consumption: typical 550 W, max 1280 W
Weight: 300 kg
Other items in other sizes – new and used – can be found in our shop!
International shipping costs upon request!
Standard Construction
For the construction of Teleperm XS systems,
SC 9422 control cabinets (2200 x 900 x 400 mm deep), IP30 protection class, are typically used.
The cabinet is equipped with cable clamps with shielding bars.
The cabinet is designed for seismic loads.
Cable entry and power supply are generally from below.
In the standard cabinet, the subracks are mounted in the middle section.
To the left and right of these are areas for mounting cabinet connection elements and transceivers.
Terminal blocks are used to connect peripheral cables.
Other connection technologies, such as Maxi-Termi-Point, are also possible.
Field cables must be shielded with twisted pairs.
Buses are implemented using conventional cables within a cabinet and fiber optic cables outside the cabinet.
Teleperm XS is suitable for systems with both surface grounding and central grounding (CEP).
Subracks
Various subrack configurations are used depending on the application.
The basic version of the subrack has a continuous backplane bus and offers 21 slots.
If large signal volumes need to be recorded, expansion subracks can be connected.
Hfodpfxotzaxme Aatjn
Variants are also supported:
- Split racks with two smaller, independent computers
(10 slots each, each with its own fans and power supply)
- Mixed configurations such as the compact combination of a computer with the associated signal conditioning modules
SC 9422 Control Cabinet
with cross bracing
Double doors
Cabinet indicator light
Height × Width × Depth: 2200 × 900 × 400 mm
Protection class: IP30
Power consumption: typical 550 W, max 1280 W
Weight: 300 kg
Other items in other sizes – new and used – can be found in our shop!