Beckman Coulter TQ-Prep Sample Preparation System for Flow CytometryBeckman Coulter
TQ-Prep
Beckman Coulter TQ-Prep Sample Preparation System for Flow Cytometry
Beckman Coulter
TQ-Prep
VB 부가세 별도
€3,025
상태
중고
위치
Borken 

기본 정보
가격 및 위치
VB 부가세 별도
€3,025
- 위치:
- Borken, 독일

전화하기
제안 세부 정보
- 광고 ID:
- A23286510
- 참조 번호:
- 75275
- 업데이트:
- 마지막 업데이트: 04.11.2026
설명
Automated sample preparation system for flow cytometry
The Beckman Coulter TQ-Prep is used for the automated preparation of whole blood samples for hematological and immunological analyses.
The system automatically performs the necessary steps, such as reagent addition, lysis processes, and other preparation procedures, ensuring reproducible analysis conditions.
These systems are primarily used in clinical laboratories, university hospitals, research institutes, and in hematological and immunological diagnostics.
Automation significantly reduces workload, sources of error, and processing times.
Areas of application:
Clinical diagnostics, hematology, immunology, research laboratories, university hospitals, diagnostic centers
Equipment and features:
- Automated preparation of whole blood samples
- Sample carousel for up to 32 tubes
- Processing of up to 32 samples in approximately 24 minutes
- Integrated incubation and lysis processes
- Precise reagent dosing via syringe pump system
- Vortex mixing system for uniform sample preparation
- Operation via touchscreen
- Use in hematology, immunology, and flow cytometry
Technical data:
Manufacturer: Beckman Coulter
Model: TQ-Prep Workstation
Model No.: 2428
Device type: Automated sample preparation system
Application: Flow cytometry
Sample material: Whole blood
Carousel capacity: 32 sample tubes
Sample throughput: Up to 32 samples / 24 minutes
Tube format: 12 × 75 mm
Reagent system: IMMUNOPREP
Reagent dosing: Syringe pump system
Mixing method: Vortex
Operation: Touchscreen
Year of manufacture: 2016
Bwedpfo Ahy Drex Adhjw
“Everything from a single source: We would be happy to offer you suitable bank financing for your project.”
More articles – new and used – can be found in our shop!
International shipping costs available upon request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
The Beckman Coulter TQ-Prep is used for the automated preparation of whole blood samples for hematological and immunological analyses.
The system automatically performs the necessary steps, such as reagent addition, lysis processes, and other preparation procedures, ensuring reproducible analysis conditions.
These systems are primarily used in clinical laboratories, university hospitals, research institutes, and in hematological and immunological diagnostics.
Automation significantly reduces workload, sources of error, and processing times.
Areas of application:
Clinical diagnostics, hematology, immunology, research laboratories, university hospitals, diagnostic centers
Equipment and features:
- Automated preparation of whole blood samples
- Sample carousel for up to 32 tubes
- Processing of up to 32 samples in approximately 24 minutes
- Integrated incubation and lysis processes
- Precise reagent dosing via syringe pump system
- Vortex mixing system for uniform sample preparation
- Operation via touchscreen
- Use in hematology, immunology, and flow cytometry
Technical data:
Manufacturer: Beckman Coulter
Model: TQ-Prep Workstation
Model No.: 2428
Device type: Automated sample preparation system
Application: Flow cytometry
Sample material: Whole blood
Carousel capacity: 32 sample tubes
Sample throughput: Up to 32 samples / 24 minutes
Tube format: 12 × 75 mm
Reagent system: IMMUNOPREP
Reagent dosing: Syringe pump system
Mixing method: Vortex
Operation: Touchscreen
Year of manufacture: 2016
Bwedpfo Ahy Drex Adhjw
“Everything from a single source: We would be happy to offer you suitable bank financing for your project.”
More articles – new and used – can be found in our shop!
International shipping costs available upon request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
등록일: 2008
531 온라인 광고
문의 보내기
전화기 & 팩스
+49 2862 ... 광고
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다












