전문 브론코스코프 세척기BHT
INNOVA E3
전문 브론코스코프 세척기
BHT
INNOVA E3
VB 부가세 별도
€6,640
제조 연도
2013
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
VB 부가세 별도
€6,640
- 위치:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A7725170
- 참조 번호:
- 25755
- 업데이트:
- 마지막 업데이트: 13.02.2026
설명
BHT INNOVA E3 Professional Bronchoscope Washer
INNOVA – Professional Endoscope Washer for Practices and Small Clinics
The INNOVA™ E3s is the world's best-selling BHT endoscope washer. This endoscope washer is compact and offers a high capacity for endoscopes or bronchoscopes. Depending on the reprocessing, a total of 10 to 20 endoscope reprocessings are possible daily. This makes it the perfect solution for private medical practices and small clinics that value safe hygiene, efficiency, and reliability.
Reliability and maximum cleanliness in every cycle:
Compliant with DIN EN ISO 15883-1/-4 and the guidelines
of the Robert Koch Institute (RKI), and with many additional functions, e.g., thermal self-disinfection at 90°C according to DIN EN ISO 15883-4, 4.8.1.
- Flexible in combination with another INNOVA® E2 or E3 for 30 to 40 reprocessings daily.
- Suitable for both glutaraldehyde and peracetic acid from a wide range of suppliers.
- Suitable for commercially available endoscopes from Fuji, Olympus, Pentax, Storz, and Wolf.
- Single-channel connection or patented pressure chamber available.
- Thermal reprocessing option, e.g., for multiple biopsy forceps, polyp loops, etc.
- Thermal disinfection of the final rinse water as recommended by the Robert Koch Institute (RKI) for the DH version.
- Secure documentation and traceability through batch control. User and endoscope identification via barcode scanner.
- Data output via printer, data logger, or computer interface. Easy integration into existing IT systems
Nedpfx Abjin Edwj Eowd
Number of endoscopes: For 2 endoscopes or 4 ENTs
Hygienic design: Hygienic workflow, single-door
Channel connection system: Single-channel connection or patented pressure chamber system possible
Single-channel monitoring system (CMS): No
Chemistry Glutaraldehyde / Peracetic Acid: Both possible: DH version (with boiler, for glutaraldehyde) or DC (filter solution, for
glutaraldehyde or peracetic acid)
Documentation and integration: Yes, interface for printer/data logger as standard. Printer as standard.
Optional scanner/IT interface
Thermal reprocessing of instruments at 90°C: Available with additional equipment
Electrical installation: 3-phase 400 V / 50 Hz AC+N+PE. Connected load: 11 kW. Fuse rating: 3 x 20 A
Year of manufacture: January 19, 2013
Item condition: used
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
INNOVA – Professional Endoscope Washer for Practices and Small Clinics
The INNOVA™ E3s is the world's best-selling BHT endoscope washer. This endoscope washer is compact and offers a high capacity for endoscopes or bronchoscopes. Depending on the reprocessing, a total of 10 to 20 endoscope reprocessings are possible daily. This makes it the perfect solution for private medical practices and small clinics that value safe hygiene, efficiency, and reliability.
Reliability and maximum cleanliness in every cycle:
Compliant with DIN EN ISO 15883-1/-4 and the guidelines
of the Robert Koch Institute (RKI), and with many additional functions, e.g., thermal self-disinfection at 90°C according to DIN EN ISO 15883-4, 4.8.1.
- Flexible in combination with another INNOVA® E2 or E3 for 30 to 40 reprocessings daily.
- Suitable for both glutaraldehyde and peracetic acid from a wide range of suppliers.
- Suitable for commercially available endoscopes from Fuji, Olympus, Pentax, Storz, and Wolf.
- Single-channel connection or patented pressure chamber available.
- Thermal reprocessing option, e.g., for multiple biopsy forceps, polyp loops, etc.
- Thermal disinfection of the final rinse water as recommended by the Robert Koch Institute (RKI) for the DH version.
- Secure documentation and traceability through batch control. User and endoscope identification via barcode scanner.
- Data output via printer, data logger, or computer interface. Easy integration into existing IT systems
Nedpfx Abjin Edwj Eowd
Number of endoscopes: For 2 endoscopes or 4 ENTs
Hygienic design: Hygienic workflow, single-door
Channel connection system: Single-channel connection or patented pressure chamber system possible
Single-channel monitoring system (CMS): No
Chemistry Glutaraldehyde / Peracetic Acid: Both possible: DH version (with boiler, for glutaraldehyde) or DC (filter solution, for
glutaraldehyde or peracetic acid)
Documentation and integration: Yes, interface for printer/data logger as standard. Printer as standard.
Optional scanner/IT interface
Thermal reprocessing of instruments at 90°C: Available with additional equipment
Electrical installation: 3-phase 400 V / 50 Hz AC+N+PE. Connected load: 11 kW. Fuse rating: 3 x 20 A
Year of manufacture: January 19, 2013
Item condition: used
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
등록일: 2008
589 온라인 광고
문의 보내기
전화기 & 팩스
+49 2862 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Zuchwil
9,036 km
청소 및 소독 장치
MMM = Münchener Medizin MechanikUniclean® PL II 15
MMM = Münchener Medizin MechanikUniclean® PL II 15
소형 광고
Wald
8,892 km
내시경 살균기 살균
SterisEPS
SterisEPS
소형 광고
Duxford
9,000 km
SMEG GW1160 유리제품 세척기
SMEGGW1160
SMEGGW1160
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다












































