온도 테스트 캐비닛 방폭CTS
T-30/950 Ex/I
온도 테스트 캐비닛 방폭
CTS
T-30/950 Ex/I
제조 연도
2011
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A7538378
- 참조 번호:
- 23117
- 업데이트:
- 마지막 업데이트: 27.06.2025
설명
CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Itsdpfx Asihb Amod Hjr
Sound pressure level:
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Itsdpfx Asihb Amod Hjr
Sound pressure level:
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Tata
8,397 km
액체 리쿨러 콘덴서
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
소형 광고
Hochdorf
8,818 km
온도 냉각 장치(TCU)
SingleCompact WK3-160-9-50 (IM160F)
SingleCompact WK3-160-9-50 (IM160F)
소형 광고
Berlin
8,335 km
축 콘덴서
Güntner AGGVH 100.2A/2x3-J(D)
Güntner AGGVH 100.2A/2x3-J(D)
소형 광고
Forst
8,830 km
100m³ 버퍼 탱크, 3bar, 단열재
소형 광고
Delmenhorst
8,529 km
1000L 압력 탱크 버퍼 저장
10539
10539
소형 광고
Schmölln
8,498 km
차가운 방
Dresdner Kühlanlagenbau
Dresdner Kühlanlagenbau
소형 광고
Niedźwiedź
8,161 km
2단 압축기 장치
BitzerS6G-25.2Y (x4)
BitzerS6G-25.2Y (x4)
소형 광고
Nattheim
8,776 km
스탠딩 패널 톱
Holz-Her1255
Holz-Her1255
소형 광고
Borken
8,705 km
습도 1000 리터의 기후 테스트 챔버
CTSC-40/1000 -40°C bis +180°C
CTSC-40/1000 -40°C bis +180°C
소형 광고
Wiefelstede
8,537 km
환기 시스템
HeimerWK-61
HeimerWK-61
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다