측정 시스템Endress+Hauser
CM442
측정 시스템
Endress+Hauser
CM442
EXW 고정 가격 부가세 별도
€500
상태
중고
위치
Sant Just Desvern 

기본 정보
가격 및 위치
EXW 고정 가격 부가세 별도
€500
- 위치:
- Av. Riera 40-A, 08960 Sant Just Desvern, España

전화하기
기술 세부 사항
치수 및 중량
총 길이:
24 mm
총 폭:
20 mm
총 높이:
16 mm
제안 세부 정보
- 광고 ID:
- A23013256
- 업데이트:
- 마지막 업데이트: 19.10.2026
설명
Liquiline CM442 Controller, ENDRESS HAUSSER - IND27827-OC - 063
Liquiline CM442 is a state-of-the-art transmitter for measuring parameters such as pH, redox, conductivity, oxygen, chlorine, turbidity, sludge level, COD, nitrate, etc.
The Liquiline CM442 transmitter allows you to connect up to 2 Memosens sensors of your choice from more than 12 measurement parameters. It automatically recognizes the sensors, is easy to operate, and features standardized spare parts that are compatible with other devices in the Liquiline platform. With its inputs, outputs, controllers, and mathematical modules, you can even control cleaning systems and dosing pumps. Heartbeat Technology helps to find the ideal balance between the availability of the measurement point and maintenance costs.
Liquiline CM442 is suitable for all industries and their auxiliary applications, such as:
Food and beverage
Life sciences
Power plants and energy
Water, wastewater, and waste
Chemicals
Marine
It features the following communication protocols and interfaces:
0/4 ... 20 mA
Nlsdpfx Asz Tl Rkendoh
HART
PROFIBUS DP
Modbus RS485/RTU
Modbus TCP
EtherNet/IP
PROFINET
Web server
The transmitter can be expanded with a module whose approvals for explosion protection, such as IECEx, ATEX, and CSA, allow it to be connected to sensors installed in areas with a risk of explosion.
Advantages
Intelligent Simplicity:
one controller for all parameters and applications, with an intuitive user interface, automatic sensor recognition, and plug & play hot-swapping with pre-calibrated Memosens sensors.
High Flexibility:
universal modules for all parameters minimize spare parts inventory and allow the system to be expanded at any time with up to 8 channels.
Direct Integration into the System:
the unique portfolio of communication standards adapts to any distributed control system (DCS).
Simple and Safe Commissioning:
the ability to save the configuration to an SD card allows for quick commissioning of duplicated installations.
Remote Process Control:
integrated web server that allows the operator to remotely view diagnostic data, perform configurations, or access the equipment parameters from any web browser, even from a smartphone.
Higher Availability, Lower Costs:
Heartbeat Technology enables condition-based maintenance and simple verification of the complete measurement point, in addition to helping you take optimization measures.
Promoting Connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, regardless of the fieldbus. This allows for an overview and the use of IIoT services. It is available in new products or as an upgrade for installed Liquiline platforms.
Summary of Specifications
Input
1 to 2 digital Memosens inputs
Output / Communication
2 to 4 current outputs of 0/4 to 20 mA
Alarm relay, 2 relays
Ingress Protection
IP 66 / IP 67
Additional Certificates
EAC, cCSAus, MCERTS
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Liquiline CM442 is a state-of-the-art transmitter for measuring parameters such as pH, redox, conductivity, oxygen, chlorine, turbidity, sludge level, COD, nitrate, etc.
The Liquiline CM442 transmitter allows you to connect up to 2 Memosens sensors of your choice from more than 12 measurement parameters. It automatically recognizes the sensors, is easy to operate, and features standardized spare parts that are compatible with other devices in the Liquiline platform. With its inputs, outputs, controllers, and mathematical modules, you can even control cleaning systems and dosing pumps. Heartbeat Technology helps to find the ideal balance between the availability of the measurement point and maintenance costs.
Liquiline CM442 is suitable for all industries and their auxiliary applications, such as:
Food and beverage
Life sciences
Power plants and energy
Water, wastewater, and waste
Chemicals
Marine
It features the following communication protocols and interfaces:
0/4 ... 20 mA
Nlsdpfx Asz Tl Rkendoh
HART
PROFIBUS DP
Modbus RS485/RTU
Modbus TCP
EtherNet/IP
PROFINET
Web server
The transmitter can be expanded with a module whose approvals for explosion protection, such as IECEx, ATEX, and CSA, allow it to be connected to sensors installed in areas with a risk of explosion.
Advantages
Intelligent Simplicity:
one controller for all parameters and applications, with an intuitive user interface, automatic sensor recognition, and plug & play hot-swapping with pre-calibrated Memosens sensors.
High Flexibility:
universal modules for all parameters minimize spare parts inventory and allow the system to be expanded at any time with up to 8 channels.
Direct Integration into the System:
the unique portfolio of communication standards adapts to any distributed control system (DCS).
Simple and Safe Commissioning:
the ability to save the configuration to an SD card allows for quick commissioning of duplicated installations.
Remote Process Control:
integrated web server that allows the operator to remotely view diagnostic data, perform configurations, or access the equipment parameters from any web browser, even from a smartphone.
Higher Availability, Lower Costs:
Heartbeat Technology enables condition-based maintenance and simple verification of the complete measurement point, in addition to helping you take optimization measures.
Promoting Connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, regardless of the fieldbus. This allows for an overview and the use of IIoT services. It is available in new products or as an upgrade for installed Liquiline platforms.
Summary of Specifications
Input
1 to 2 digital Memosens inputs
Output / Communication
2 to 4 current outputs of 0/4 to 20 mA
Alarm relay, 2 relays
Ingress Protection
IP 66 / IP 67
Additional Certificates
EAC, cCSAus, MCERTS
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
등록일: 2022
24 온라인 광고
문의 보내기
전화기 & 팩스
+34 614 1... 광고
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다