기후 테스트 챔버 280리터Feutron
KPK 200 Typ: 3416/16 +5 °C bis +100 °C
기후 테스트 챔버 280리터
Feutron
KPK 200 Typ: 3416/16 +5 °C bis +100 °C
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A8059298
- 참조 번호:
- 23348
- 업데이트:
- 마지막 업데이트: 15.11.2024
설명
Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
Kfjdpfoiz Tqcox Ad Hoa
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
Kfjdpfoiz Tqcox Ad Hoa
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Langenfeld (Rheinland)
8,759 km
가구
Großbüro Auflösung, Büromöbel, DauphinInterstuhl, FM, only 10 each left
Großbüro Auflösung, Büromöbel, DauphinInterstuhl, FM, only 10 each left
소형 광고
Wuppertal
8,744 km
과립 및 분말용 건조 시스템
AGRIFON
AGRIFON
소형 광고
Fliessem
8,866 km
전면 적재 포크리프트
LINDEH 80-900 EVO
LINDEH 80-900 EVO
소형 광고
Dievogala
7,625 km
식품 건조기 - 제습기
DG200
DG200
소형 광고
Wehr
8,983 km
빠른 체
Labor TecTR 80
Labor TecTR 80
소형 광고
Treuchtlingen
8,724 km
오일 온도 조절 장치
Rummel Kunststofftechnik GmbHTEMP2 150 9A SSR
Rummel Kunststofftechnik GmbHTEMP2 150 9A SSR
소형 광고
Delmenhorst
8,529 km
탱크
Inox Behälter GmbHEBB150RWAD
Inox Behälter GmbHEBB150RWAD
소형 광고
Borken
8,705 km
습도가 있는 기후 테스트 캐비닛
WeissSB2/500/80 -75°C bis +180°C
WeissSB2/500/80 -75°C bis +180°C
소형 광고
Borken
8,705 km
기후실
CTSC-40/200
CTSC-40/200
소형 광고
Borken
8,705 km
진공 건조 오븐
PINKVT 300-600-300-1
PINKVT 300-600-300-1
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다