GBS Prüfpuls rev3 Pulse generator for long-term insulation tests
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
Dsdpfx Aju Egz Rom Sskw
More items - new and used - can be found in our shop!
International shipping costs on request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
Dsdpfx Aju Egz Rom Sskw
More items - new and used - can be found in our shop!
International shipping costs on request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
등록일: 2008
535 온라인 광고
문의 보내기
전화기 & 팩스
+49 2862 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Wiefelstede
8,537 km
벤치 바이스 150mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다