부식 시험 장치 염수 분무 챔버Gebr. Liebisch
S 1000 A-TR / 42016211
부식 시험 장치 염수 분무 챔버
Gebr. Liebisch
S 1000 A-TR / 42016211
상태
중고
위치
Borken 

기계 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A19029211
- 참조 번호:
- 24609
- 업데이트:
- 마지막 업데이트: 28.04.2025
설명
Liebisch
Type: S 1000 A-TR / 42016211
Chest-mounted units with a 1000-liter test chamber volume for salt spray testing.
Constamatic® TR
This series includes automatically controlled chest-mounted units of type A-TR.
The internal controls are operated via a touchscreen.
All functions are displayed on a touchscreen with intuitive user guidance.
Technical specifications:
Device type: S 1000 A-TR
External housing dimensions: (W x D x H in mm) 2600 x 1120 x 1210
Internal test chamber dimensions: (W x D x H in mm) 1535/1425 x 800/780 x 660/650
Max. sample holder load: 10 kg / level 10 kg
Operating voltage: 230 V +6/-10%
Power consumption S: 2700 W
Humidity control range. S: up to / 70°C
Godpfx Aaewf Dh No Ejbl
Test chamber control range K: up to / 50°C
Test chamber control range S: up to / 50°C
Frequency: 50/60 Hz
Device fuse: 12 A
Temperature control: PLC
Overtemperature protection: yes
Test chamber volume: 1000 liters
Test solution storage capacity: approx. / 150 liters
Test solution consumption per hour: approx. / 0.7 - 1.0 liters
Water filling of base pan KON: 15 liters
Weight: 450 kg
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Type: S 1000 A-TR / 42016211
Chest-mounted units with a 1000-liter test chamber volume for salt spray testing.
Constamatic® TR
This series includes automatically controlled chest-mounted units of type A-TR.
The internal controls are operated via a touchscreen.
All functions are displayed on a touchscreen with intuitive user guidance.
Technical specifications:
Device type: S 1000 A-TR
External housing dimensions: (W x D x H in mm) 2600 x 1120 x 1210
Internal test chamber dimensions: (W x D x H in mm) 1535/1425 x 800/780 x 660/650
Max. sample holder load: 10 kg / level 10 kg
Operating voltage: 230 V +6/-10%
Power consumption S: 2700 W
Humidity control range. S: up to / 70°C
Godpfx Aaewf Dh No Ejbl
Test chamber control range K: up to / 50°C
Test chamber control range S: up to / 50°C
Frequency: 50/60 Hz
Device fuse: 12 A
Temperature control: PLC
Overtemperature protection: yes
Test chamber volume: 1000 liters
Test solution storage capacity: approx. / 150 liters
Test solution consumption per hour: approx. / 0.7 - 1.0 liters
Water filling of base pan KON: 15 liters
Weight: 450 kg
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Gondelsheim
8,832 km
크레인 스카이 크레인 실내 크레인 크레인 활주로
Demag - Portalkran KBK 125KG KettenzugKBK 1 KBK1 12x3,5m NL 125Kg + Zubehör
Demag - Portalkran KBK 125KG KettenzugKBK 1 KBK1 12x3,5m NL 125Kg + Zubehör
소형 광고
Lindlar
8,747 km
연마 기
PM 1000
PM 1000
소형 광고
Borken
8,705 km
염수 분무 챔버
WeissSC/KWT 450
WeissSC/KWT 450
소형 광고
Lindlar
8,747 km
연마 기
Weiz Industrie- und RobotertechnikRPM500_OSZ2
Weiz Industrie- und RobotertechnikRPM500_OSZ2
소형 광고
Borken
8,705 km
190L 온도 테스트 캐비닛
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
소형 광고
Ljubljana
8,732 km
레이저 절단 기계
Bodor P3 6kw
Bodor P3 6kw
소형 광고
Hanau
8,734 km
고무 가공 기계
Alpha TechnologiesGummiprüfgeräte MDR
Alpha TechnologiesGummiprüfgeräte MDR
소형 광고
독일
8,705 km
염수 분무 챔버 부식 챔버
KöhlerHKT 500 WTG
KöhlerHKT 500 WTG
소형 광고
Skarżysko-Kamienna
8,015 km
분말 코팅 장비
ROMER-malowanie elektrostatyczneKompleksowe lakiernie proszkowe
ROMER-malowanie elektrostatyczneKompleksowe lakiernie proszkowe
소형 광고
Borken
8,705 km
염수 분무용 부식 테스트 캐비닛
VLMCC 1000-FL HL V.745.672.120
VLMCC 1000-FL HL V.745.672.120
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다