Heraeus Vötsch Climate Test Chamber
We offer you a Heraeus Vötsch climate test chamber.
Model: VC³ 0100
Test chamber dimensions (H x W x D): approx. 950 x 1100 x 950 mm
TEMPERATURE TESTS:
- Minimum temperature: -0°C
- Maximum temperature: +90°C
- Temperature change rate (cooling): 0.2 K/min
- Temperature change rate (heating): 0.5 K/min
- Temporal temperature deviation: ± 0.1 to ± 0.5 K
- Spatial temperature uniformity: ± 0.5 to ± 1.0 K
- Heat compensation at +20°C: 350W
CLIMATE TESTS:
- Minimum temperature: +10°C
- Maximum temperature: +90°C
- Dew point temperature range: +4°C to +89.5°C
- Humidity range: 10 to 98% r.h.
- Temporal humidity deviation: ± 1 to ± 3% r.h.
- Temporal temperature deviation: ± 0.1 to ± 0.3 K
- Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Nominal power: 2.6 kW
Nominal current: 12 A
Refrigerant: R 404A
Weight: approx. 1400 kg
For your security as a buyer, please note:
The following procedures are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
Bcedpfjyguv Ejx Agmsu
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented trial run.
Type: VC³ 0100 / Year of manufacture: 2013
Condition: used
Scope of delivery: (see picture)
(Technical data and specifications subject to change or error!)
Further questions? We will be happy to answer them by telephone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
We offer you a Heraeus Vötsch climate test chamber.
Model: VC³ 0100
Test chamber dimensions (H x W x D): approx. 950 x 1100 x 950 mm
TEMPERATURE TESTS:
- Minimum temperature: -0°C
- Maximum temperature: +90°C
- Temperature change rate (cooling): 0.2 K/min
- Temperature change rate (heating): 0.5 K/min
- Temporal temperature deviation: ± 0.1 to ± 0.5 K
- Spatial temperature uniformity: ± 0.5 to ± 1.0 K
- Heat compensation at +20°C: 350W
CLIMATE TESTS:
- Minimum temperature: +10°C
- Maximum temperature: +90°C
- Dew point temperature range: +4°C to +89.5°C
- Humidity range: 10 to 98% r.h.
- Temporal humidity deviation: ± 1 to ± 3% r.h.
- Temporal temperature deviation: ± 0.1 to ± 0.3 K
- Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Nominal power: 2.6 kW
Nominal current: 12 A
Refrigerant: R 404A
Weight: approx. 1400 kg
For your security as a buyer, please note:
The following procedures are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
Bcedpfjyguv Ejx Agmsu
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented trial run.
Type: VC³ 0100 / Year of manufacture: 2013
Condition: used
Scope of delivery: (see picture)
(Technical data and specifications subject to change or error!)
Further questions? We will be happy to answer them by telephone.