Hitech Instruments GIR250 가스 분석기
Hitech Instruments GIR250

상태
중고
위치
Duxford 영국
Hitech Instruments GIR250 가스 분석기 Hitech Instruments GIR250
Hitech Instruments GIR250 가스 분석기 Hitech Instruments GIR250
Hitech Instruments GIR250 가스 분석기 Hitech Instruments GIR250
Hitech Instruments GIR250 가스 분석기 Hitech Instruments GIR250
Hitech Instruments GIR250 가스 분석기 Hitech Instruments GIR250
Hitech Instruments GIR250 가스 분석기 Hitech Instruments GIR250
more Images
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
사진은 보여줍니다
지도 표시

기계 정보

기계 명칭:
Hitech Instruments GIR250 가스 분석기
제조업체:
Hitech Instruments
모델:
GIR250
상태:
중고

가격 및 위치

위치:
Duxford, UK 영국
전화하기

제안 세부 정보

광고 ID:
A20123055
참조 번호:
240850/7B
업데이트:
마지막 업데이트: 02.10.2025

설명

This listing is for the Hitech Instruments GIR250 Gas Analyser

The unit is in full working condition and is ready for immediate use

The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.

It is made by Hitech Instruments (now part of the MTL / Eaton group).

Its design emphasizes ease of use, reliability, and low maintenance cost.

Other supporting features:

The instrument can be programmed with pass/fail criteria for each gas (alarms).

It provides analog outputs, typically 4–20 mA, for external logging or control systems.

Calibration is designed to be simple (via the front panel keypad) to reduce training burden.

The O₂ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).

Mechanical, Electrical & Operational Details

The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.
Hfsdpfjxhdqtsx Aaten

Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.

The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.

Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)

Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)

Typical Applications & Suitability

Because it can measure both O₂ and CO₂ in a single unit, the GIR250 is used in applications such as:

Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)

Fermentation / bioprocess monitoring (where O₂ and CO₂ both matter)

Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)

It is not primarily intended for measuring very low trace levels (ppm-level) of O₂ or CO₂ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis

공급자

등록일: 2019

524 온라인 광고

전화하기

문의 보내기

토지us 
독일
오스트리아
스위스
미국
영국
프랑스
벨기에
스페인
멕시코
이탈리아
네덜란드
폴란드
러시아 연방
벨라루스(벨라루스 공화국)
우크라이나
에스토니아
터키
뉴질랜드
아일랜드
체코 공화국
덴마크
핀란드
스웨덴
노르웨이
룩셈부르크
그리스
리투아니아
라트비아
아이슬란드
포르투갈
브라질
베네수엘라
아르헨티나
헝가리
슬로바키아
루마니아
몰도바
슬로베니아
세르비아
몬테네그로
알바니아
크로아티아
불가리아
북마케도니아
보스니아 헤르체고비나
이스라엘
이집트
모로코
인도
인도네시아
대한민국
일본
태국
말레이시아
베트남
China
대만
이란
방글라데시
아프가니스탄
참고: 귀하의 요청은 기계 카테고리의 모든 판매자에게 전달됩니다. 이를 통해 매우 많은 제안을 받을 수 있습니다.
요청을 보낼 수 없습니다. 나중에 다시 시도하십시오.

전화기 & 팩스

+44 20 38... 광고