오염 통제 장치가 장착된 유해 폐기물 소각로Inciner8 International Ltd., United King
Inciner8 I8-1000
오염 통제 장치가 장착된 유해 폐기물 소각로
Inciner8 International Ltd., United King
Inciner8 I8-1000
EXW 고정 가격 부가세 별도
€1,920,000
제조 연도
2018
상태
중고
위치
Devnya 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
EXW 고정 가격 부가세 별도
€1,920,000
- 위치:
- Devnya, Bulgaria
전화하기
기술 세부 사항
- 총 길이:
- 6,490 mm
- 총 폭:
- 2,000 mm
- 총 높이:
- 6,260 mm
- 총중량:
- 21,500 kg
- 동력:
- 44 킬로와트 (59.82 마력)
- 장비:
- 문서 / 매뉴얼
제안 세부 정보
- 광고 ID:
- A20220510
- 참조 번호:
- INCIN8(G)1451
- 업데이트:
- 마지막 업데이트: 17.10.2025
설명
Hazardous Waste Incineration Plant – Inciner8 I8-1000
Location: Devnya, Bulgaria
Manufacturer: Inciner8 International Ltd., United Kingdom
Year of manufacture: 2018
Condition: Installed, fully operational, complete documentation and CE certification
General Description
The Inciner8 I8-1000 is a high-performance system for thermal treatment of hazardous and industrial waste, featuring fully automatic loading, dual-chamber combustion, and an integrated flue-gas cleaning system.
Designed for ease of operation, robust construction, and long service life, the unit ensures full compliance with EU Directive 2000/76/EC and the European Industrial Emissions Directive (IED).
The system guarantees complete oxidation of waste under controlled temperature and residence time, resulting in non-hazardous ash and emissions meeting EU regulatory limits.
Main Technical Parameters:
• Type: Dual-chamber incinerator with secondary afterburner
• Model: Inciner8 I8-1000 C/W Eco Flam Burners
• Feeding capacity: up to 330 kg per batch (automatically adjusted to waste type)
• Combustion temperatures: Primary 800–1100 °C | Secondary ≥ 850 °C (2 s residence time)
• Loading system: Hydraulic RAM feeder with automatic door and safety interlocks
• Auxiliary fuel: Low-NOx diesel burners (two-stage surface-stabilized combustion)
• Operation mode: Underpressure – 2 mbar (ID fan with frequency control)
• Heat recovery: Air-cooled heat exchanger for waste-heat utilization (up to 400 °C)
Flue-Gas Cleaning System (Pollution Control System – PCS):
Three-stage treatment:
1. Heat exchanger – rapid cooling of flue gases below 425 °C
2. Powder dosing unit – hydrated lime/limestone injection for neutralization of acid gases (HCl, SO₂, HF)
3. Ceramic candle filter – final filtration of particulates, heavy metals, and residual compounds
Key features:
• Ceramic filter candles with automatic reverse-pulse cleaning
• Particulate emissions (PM₁₀ / PM₂.₅) < 1 mg/Nm³
• Integrated system preventing de novo dioxin formation by maintaining temperature > 800 °C and removing chlorine compounds
Continuous Emission Monitoring System (CEMS):
• Measured parameters: O₂, CO, CO₂, NO, NO₂, HCl, HF, TOC, particulates, humidity, pressure, temperature
• Ranges: in accordance with EN 14181 (O₂ 0–25%, CO 0–4000 ppm, etc.)
• Data management: USB / Internet output, software package included
Certification & Compliance:
• CE Declarations of Conformity for the complete system and subsystems (autoloader, ID fan, PCS)
• Manufacturer ISO quality certification
• Complies with EU Directives: 2006/42/EC (Machinery), 2014/35/EU (Low Voltage), 2014/30/EU (EMC)
• Emission testing: QUAL 1 Test Report No. 05/24-01-2019 – confirmed compliance with 2000/76/EC
Advantages:
• Fully automated and safe operation with PLC control
• Suitable for hazardous, medical, and industrial waste streams
• Minimal residual ash and low OPEX
• Heat recovery option for hot-water utilization
Iijdoxlcw Tjpfx Aateh
• The system is ready for dismantling and relocation
Delivery terms: EXW Devnya, Bulgaria (Ex Works – pickup from site)
Location: Devnya, Bulgaria
Manufacturer: Inciner8 International Ltd., United Kingdom
Year of manufacture: 2018
Condition: Installed, fully operational, complete documentation and CE certification
General Description
The Inciner8 I8-1000 is a high-performance system for thermal treatment of hazardous and industrial waste, featuring fully automatic loading, dual-chamber combustion, and an integrated flue-gas cleaning system.
Designed for ease of operation, robust construction, and long service life, the unit ensures full compliance with EU Directive 2000/76/EC and the European Industrial Emissions Directive (IED).
The system guarantees complete oxidation of waste under controlled temperature and residence time, resulting in non-hazardous ash and emissions meeting EU regulatory limits.
Main Technical Parameters:
• Type: Dual-chamber incinerator with secondary afterburner
• Model: Inciner8 I8-1000 C/W Eco Flam Burners
• Feeding capacity: up to 330 kg per batch (automatically adjusted to waste type)
• Combustion temperatures: Primary 800–1100 °C | Secondary ≥ 850 °C (2 s residence time)
• Loading system: Hydraulic RAM feeder with automatic door and safety interlocks
• Auxiliary fuel: Low-NOx diesel burners (two-stage surface-stabilized combustion)
• Operation mode: Underpressure – 2 mbar (ID fan with frequency control)
• Heat recovery: Air-cooled heat exchanger for waste-heat utilization (up to 400 °C)
Flue-Gas Cleaning System (Pollution Control System – PCS):
Three-stage treatment:
1. Heat exchanger – rapid cooling of flue gases below 425 °C
2. Powder dosing unit – hydrated lime/limestone injection for neutralization of acid gases (HCl, SO₂, HF)
3. Ceramic candle filter – final filtration of particulates, heavy metals, and residual compounds
Key features:
• Ceramic filter candles with automatic reverse-pulse cleaning
• Particulate emissions (PM₁₀ / PM₂.₅) < 1 mg/Nm³
• Integrated system preventing de novo dioxin formation by maintaining temperature > 800 °C and removing chlorine compounds
Continuous Emission Monitoring System (CEMS):
• Measured parameters: O₂, CO, CO₂, NO, NO₂, HCl, HF, TOC, particulates, humidity, pressure, temperature
• Ranges: in accordance with EN 14181 (O₂ 0–25%, CO 0–4000 ppm, etc.)
• Data management: USB / Internet output, software package included
Certification & Compliance:
• CE Declarations of Conformity for the complete system and subsystems (autoloader, ID fan, PCS)
• Manufacturer ISO quality certification
• Complies with EU Directives: 2006/42/EC (Machinery), 2014/35/EU (Low Voltage), 2014/30/EU (EMC)
• Emission testing: QUAL 1 Test Report No. 05/24-01-2019 – confirmed compliance with 2000/76/EC
Advantages:
• Fully automated and safe operation with PLC control
• Suitable for hazardous, medical, and industrial waste streams
• Minimal residual ash and low OPEX
• Heat recovery option for hot-water utilization
Iijdoxlcw Tjpfx Aateh
• The system is ready for dismantling and relocation
Delivery terms: EXW Devnya, Bulgaria (Ex Works – pickup from site)