설명
Here, we offer you an Iridex laser system, the OcuLight SLx.
Laser IRIDEX Oculight SLx Tri-Mode 810 nm Diode Laser
Description:
Designed for longevity, with a thermal management system to increase the efficiency and reliability of laser conversion.
Improved user interface with conveniently arranged, easy-to-understand controls.
Enables easy transport between rooms and offices.
The tri-mode capability offers three different laser energy delivery modes: CW-Pulse, MicroPulse, and Long-Pulse.
An extremely ergonomic user interface, infrared wavelength, and a wide range of delivery systems offer a broad spectrum of treatment options.
Well-suited for retinopathy of prematurity and end-stage glaucoma.
The CW-Pulse mode delivers energy in single or repeated exposures.
The LongPulse mode delivers laser energy over longer periods.
The MicroPulse mode delivers laser energy in a series of short pulses, allowing for fine control of the thermal effects.
Features:
Application area: ophthalmology
Amplifier medium: solid-state
Ergonomics: table-top unit
Wavelength: 810 nm
Treatment laser power: infrared diode laser 810 nm, 0–3000 mW
Target laser power: red diode laser 650–670 nm, 0 to < 1.0 mW
Delivery devices: EndoProbe, TruFocus LIO, portable SLAs, DioPexy, G-Probe, Large-Spot-SLAs, LIO and OMAs
Exposure durations: CW-Pulse 10-9000 ms, MicroPulse 0.1-1.0 ms, LongPulse 10s-30 min
No external air or water cooling required.
Isdpfx Aezd Uubeikoic
Weight: 6.4 kg
Length: 10 mm
Width: 30 mm
Height: 30 mm
Clinical applications:
The Oculight SLx laser system can be used to perform retinal photocoagulation and glaucoma procedures.
While this infrared laser (810 nm) can be used for conventional photocoagulation, it also has some unique treatment options, such as:
transscleral retinal photocoagulation for retinal tears and detachments,
transscleral cyclophotocoagulation for refractive glaucoma,
transpupillary thermotherapy photocoagulation for choroidal lesions, and
MicroPulse photocoagulation below the threshold for diabetic retinopathy and age-related macular degeneration (AMD).
Laser-indirect ophthalmoscope (LIO)
The TruFocus Laser Indirect Ophthalmoscope (LIO) is ideal for patients who are best examined and treated in the supine position.
It is considered to have a unique optical design in the industry, which eliminates the need to adjust the laser focus and allows for a wide range of working distances.
Type: Iridex OcuLight SLx
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have over the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Laser IRIDEX Oculight SLx Tri-Mode 810 nm Diode Laser
Description:
Designed for longevity, with a thermal management system to increase the efficiency and reliability of laser conversion.
Improved user interface with conveniently arranged, easy-to-understand controls.
Enables easy transport between rooms and offices.
The tri-mode capability offers three different laser energy delivery modes: CW-Pulse, MicroPulse, and Long-Pulse.
An extremely ergonomic user interface, infrared wavelength, and a wide range of delivery systems offer a broad spectrum of treatment options.
Well-suited for retinopathy of prematurity and end-stage glaucoma.
The CW-Pulse mode delivers energy in single or repeated exposures.
The LongPulse mode delivers laser energy over longer periods.
The MicroPulse mode delivers laser energy in a series of short pulses, allowing for fine control of the thermal effects.
Features:
Application area: ophthalmology
Amplifier medium: solid-state
Ergonomics: table-top unit
Wavelength: 810 nm
Treatment laser power: infrared diode laser 810 nm, 0–3000 mW
Target laser power: red diode laser 650–670 nm, 0 to < 1.0 mW
Delivery devices: EndoProbe, TruFocus LIO, portable SLAs, DioPexy, G-Probe, Large-Spot-SLAs, LIO and OMAs
Exposure durations: CW-Pulse 10-9000 ms, MicroPulse 0.1-1.0 ms, LongPulse 10s-30 min
No external air or water cooling required.
Isdpfx Aezd Uubeikoic
Weight: 6.4 kg
Length: 10 mm
Width: 30 mm
Height: 30 mm
Clinical applications:
The Oculight SLx laser system can be used to perform retinal photocoagulation and glaucoma procedures.
While this infrared laser (810 nm) can be used for conventional photocoagulation, it also has some unique treatment options, such as:
transscleral retinal photocoagulation for retinal tears and detachments,
transscleral cyclophotocoagulation for refractive glaucoma,
transpupillary thermotherapy photocoagulation for choroidal lesions, and
MicroPulse photocoagulation below the threshold for diabetic retinopathy and age-related macular degeneration (AMD).
Laser-indirect ophthalmoscope (LIO)
The TruFocus Laser Indirect Ophthalmoscope (LIO) is ideal for patients who are best examined and treated in the supine position.
It is considered to have a unique optical design in the industry, which eliminates the need to adjust the laser focus and allows for a wide range of working distances.
Type: Iridex OcuLight SLx
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)