클린룸 ISO 8
클린룸 ISO 8
EXW VB 부가세 별도
€50,000
제조 연도
2020
상태
중고
(완전히 작동합니다)
위치
Łódź 

기계 정보
가격 및 위치
EXW VB 부가세 별도
€50,000
- 위치:
- Łódź, 폴란드

전화하기
제안 세부 정보
- 광고 ID:
- A14477200
- 업데이트:
- 마지막 업데이트: 02.01.2024
설명
CLEANROOM - ISO 8
| Cleanroom requirements ISO Class 8 | ISO Cleanroom Class 8 | Cleanroom classification.
In order to achieve an ISO 8 air purity class in a Cleanroom, several levels of air filtration are usually used (e.g. G4 pre-filter, F9 filter, H13 final filter). Air movement in the room is non-unidirectional (there is a mixing of "clean" air supplied to the room with "dirty" air present in the room). Air vents in the ISO 8 room are placed on the walls. The required number of air exchanges per hour will depend on the nature of the activities conducted in the room and the number of personnel present, but the goal could be to provide 10-40 air exchanges/hr. In ISO Class 8, personnel are often present continuously. Employees may be dressed in standard work attire and visitors in a disposable apron. It is recommended to maintain a minimum overpressure of the room relative to the adjacent zone of 5-10 Pa.
Requirements for equipment and materials intended for Clean Room with ISO air cleanliness class 8 (maximum average amount of particles released when: number of samples taken = 100; measurement performed in accordance with ISO 14644-14 in a cleanliness class at least one better than the purpose of the device; number of particles/m3) Detailed description in photos.
Bwjdpfsq H H Rujx Ai Nop
Technical drawings attached to photos.
Description of ventilation
The purpose of the ventilation installation performed was to achieve the following air parameters in the Clean Room. The installation was made with the GBD PHARMA 2000 system, meeting all the requirements for 'clean rooms' in the highest classes of air purity.
Parameters for the installation: a. Air purity - ISO 8. b. Temperature 19-23 st C
c. Humidity max 38%.
a. To ensure the required purity of the supplied air, an air handling unit manufactured by DOSPEL with a maximum capacity of V= 3500 m3/h [up to 15 air changes per hour] was used. The air handling unit is equipped with pocket filters : pre-filters FK EU5/EC2 and fine filters FK-EU9/EC2. In addition, HEPA 11 filters made by EUFILTER were used in diffusers located in the ceiling. Data sheets in point H6.
As a result , with a measured flow rate of 3264 m3/h, an ISO 7 [class "C"] cleanliness class of the room was obtained in the resting state, and thus an ISO 8 [class "D" ] cleanliness class for the working state.
b. The temperature range of 19-23 deg C is for the enlarged cooler and chiller to be freely maintained with 25% fresh air.
c. In order to achieve in summer conditions with high temperatures of 30 deg C and humidity of 80%, a freon chiller of 31.4 kW and a chiller of 33.5 kW of cooling power were used. The chiller is made by FUJITSU supplied by Klimatherm Gdansk.
The room is automatically regulated overpressure in relation to the external pressure - the pressure difference at the door : 15 Pa
The automation of ventilation allows for "economical" mode , in which the installation works in a closed circuit and an overpressure of 15 Pa is maintained.
Technical data attached to the photos.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
| Cleanroom requirements ISO Class 8 | ISO Cleanroom Class 8 | Cleanroom classification.
In order to achieve an ISO 8 air purity class in a Cleanroom, several levels of air filtration are usually used (e.g. G4 pre-filter, F9 filter, H13 final filter). Air movement in the room is non-unidirectional (there is a mixing of "clean" air supplied to the room with "dirty" air present in the room). Air vents in the ISO 8 room are placed on the walls. The required number of air exchanges per hour will depend on the nature of the activities conducted in the room and the number of personnel present, but the goal could be to provide 10-40 air exchanges/hr. In ISO Class 8, personnel are often present continuously. Employees may be dressed in standard work attire and visitors in a disposable apron. It is recommended to maintain a minimum overpressure of the room relative to the adjacent zone of 5-10 Pa.
Requirements for equipment and materials intended for Clean Room with ISO air cleanliness class 8 (maximum average amount of particles released when: number of samples taken = 100; measurement performed in accordance with ISO 14644-14 in a cleanliness class at least one better than the purpose of the device; number of particles/m3) Detailed description in photos.
Bwjdpfsq H H Rujx Ai Nop
Technical drawings attached to photos.
Description of ventilation
The purpose of the ventilation installation performed was to achieve the following air parameters in the Clean Room. The installation was made with the GBD PHARMA 2000 system, meeting all the requirements for 'clean rooms' in the highest classes of air purity.
Parameters for the installation: a. Air purity - ISO 8. b. Temperature 19-23 st C
c. Humidity max 38%.
a. To ensure the required purity of the supplied air, an air handling unit manufactured by DOSPEL with a maximum capacity of V= 3500 m3/h [up to 15 air changes per hour] was used. The air handling unit is equipped with pocket filters : pre-filters FK EU5/EC2 and fine filters FK-EU9/EC2. In addition, HEPA 11 filters made by EUFILTER were used in diffusers located in the ceiling. Data sheets in point H6.
As a result , with a measured flow rate of 3264 m3/h, an ISO 7 [class "C"] cleanliness class of the room was obtained in the resting state, and thus an ISO 8 [class "D" ] cleanliness class for the working state.
b. The temperature range of 19-23 deg C is for the enlarged cooler and chiller to be freely maintained with 25% fresh air.
c. In order to achieve in summer conditions with high temperatures of 30 deg C and humidity of 80%, a freon chiller of 31.4 kW and a chiller of 33.5 kW of cooling power were used. The chiller is made by FUJITSU supplied by Klimatherm Gdansk.
The room is automatically regulated overpressure in relation to the external pressure - the pressure difference at the door : 15 Pa
The automation of ventilation allows for "economical" mode , in which the installation works in a closed circuit and an overpressure of 15 Pa is maintained.
Technical data attached to the photos.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
등록일: 2023
1 온라인 광고
문의 보내기
전화기 & 팩스
+48 728 4... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Hessen
8,714 km
프레스 브레이크
WeinbrennerTSV 8/3050
WeinbrennerTSV 8/3050
소형 광고
Meiningen
8,624 km
순환식 오븐 300°C 전기식
Ingenieurbüro Klein mit Umluft, NanodacUK 8820-300
Ingenieurbüro Klein mit Umluft, NanodacUK 8820-300
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Бургас
8,146 km
산업용 로봇
KUKAKR 500 L420-2
KUKAKR 500 L420-2
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Nordrhein-Westfalen
8,715 km
CNC 선반 및 밀링 센터
CMZTA-30-TY 640 + GL20II
CMZTA-30-TY 640 + GL20II
소형 광고
Ahaus
8,681 km
기둥 지브 크레인
ABUSLS / 4000 MM x 1000 KG
ABUSLS / 4000 MM x 1000 KG
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Бургас
8,151 km
산업용 로봇
ABBIRB 7600 - 340
ABBIRB 7600 - 340
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Středočeský kraj
8,474 km
CNC 선반
MazakIntegrex 200 III ST
MazakIntegrex 200 III ST
소형 광고
독일
8,579 km
대류 오븐
NaberthermN500/65HA
NaberthermN500/65HA
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Středočeský kraj
8,474 km
CNC 선반
HURCOTM 10
HURCOTM 10
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Středočeský kraj
8,474 km
CNC 선반
COLCHESTERAlpha 1400XS
COLCHESTERAlpha 1400XS
소형 광고
Hradec Králové
8,362 km
야채 절단기
Urschel1700
Urschel1700
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Středočeský kraj
8,474 km
CNC 선반
MiyanoLZ 02RY
MiyanoLZ 02RY
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Софийска област
8,409 km
진공성형기
KiefelKMD 52 BFS
KiefelKMD 52 BFS
소형 광고
Enschede
8,676 km
튜브 레이저 절단기
Bodor K2
Bodor K2
경매
종료까지
d
h
min
s
경매가 종료되었습니다
Nordrhein-Westfalen
8,720 km
레이저 절단기
TRUMPFTruLaser 1030 (L22) Coax
TRUMPFTruLaser 1030 (L22) Coax
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다