모듈 FCM-1200 220V GPIBMettler Toledo
AutoChem FCM Fluid Control
모듈 FCM-1200 220V GPIB
Mettler Toledo
AutoChem FCM Fluid Control
고정 가격 부가세 별도
€3,650
상태
중고
위치
Borken 

기본 정보
가격 및 위치
고정 가격 부가세 별도
€3,650
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A22539942
- 참조 번호:
- 25467
- 업데이트:
- 마지막 업데이트: 12.08.2026
설명
Mettler Toledo AutoChem FCM Fluid Control Module
Manufacturer: Mettler Toledo
Model: FCM
Part Number: 16000903
Machine Type: Fluid Control Module / Fluid Handling Module
Line Voltage: 220 VAC
Line Frequency: 50/60 Hz
Offered is a Mettler Toledo AutoChem FCM Fluid Control Module for corresponding laboratory, reaction, and process systems.
The device features an integrated Mettler Toledo FCM-1200 Modifier Fluid Pump, as well as the associated fluid lines, fittings, and connections.
The module is designed for the controlled delivery or handling of fluids within corresponding Mettler Toledo AutoChem systems.
Technical Data:
Manufacturer: Mettler Toledo
Model: FCM
Part Number: 16000903
Line Voltage: 220 VAC
Line Frequency: 50/60 Hz
Fusing: 4 A Time Delay
Integrated Pump: FCM-1200 Modifier Fluid Pump
Pump Part Number: 16001176
Interfaces / Connections:
2x REMOTE interface
GPIB interface
Front-side INLET/OUTLET connections
Additional fluid connections on the rear of the device
IEC power connector
Dimensions:
Width: approx. 450 mm
Depth: approx. 650 mm
Height: approx. 550 mm
Dimensions W x D x H: approx. 450 x 650 x 550 mm
Equipment:
Mettler Toledo FCM-1200 Modifier Fluid Pump
Chjdpfx Apszt Nzhocec
Integrated fluid lines and fittings
INLET/OUTLET connections
REMOTE interfaces
GPIB interface
Status indicators
Metal housing with side service panel
Shipping Data:
Weight: approx. 50 kg
Due to its size and weight, shipping by freight forwarder is planned.
Condition:
Used condition with signs of wear and tear consistent with age and use.
The exact technical functionality has not been further verified.
Condition and design, see product images.
Scope of Delivery:
1x Mettler Toledo AutoChem FCM Fluid Control Module as shown.
The scope of delivery corresponds to the product images.
Subject to changes, errors, and prior sale.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Manufacturer: Mettler Toledo
Model: FCM
Part Number: 16000903
Machine Type: Fluid Control Module / Fluid Handling Module
Line Voltage: 220 VAC
Line Frequency: 50/60 Hz
Offered is a Mettler Toledo AutoChem FCM Fluid Control Module for corresponding laboratory, reaction, and process systems.
The device features an integrated Mettler Toledo FCM-1200 Modifier Fluid Pump, as well as the associated fluid lines, fittings, and connections.
The module is designed for the controlled delivery or handling of fluids within corresponding Mettler Toledo AutoChem systems.
Technical Data:
Manufacturer: Mettler Toledo
Model: FCM
Part Number: 16000903
Line Voltage: 220 VAC
Line Frequency: 50/60 Hz
Fusing: 4 A Time Delay
Integrated Pump: FCM-1200 Modifier Fluid Pump
Pump Part Number: 16001176
Interfaces / Connections:
2x REMOTE interface
GPIB interface
Front-side INLET/OUTLET connections
Additional fluid connections on the rear of the device
IEC power connector
Dimensions:
Width: approx. 450 mm
Depth: approx. 650 mm
Height: approx. 550 mm
Dimensions W x D x H: approx. 450 x 650 x 550 mm
Equipment:
Mettler Toledo FCM-1200 Modifier Fluid Pump
Chjdpfx Apszt Nzhocec
Integrated fluid lines and fittings
INLET/OUTLET connections
REMOTE interfaces
GPIB interface
Status indicators
Metal housing with side service panel
Shipping Data:
Weight: approx. 50 kg
Due to its size and weight, shipping by freight forwarder is planned.
Condition:
Used condition with signs of wear and tear consistent with age and use.
The exact technical functionality has not been further verified.
Condition and design, see product images.
Scope of Delivery:
1x Mettler Toledo AutoChem FCM Fluid Control Module as shown.
The scope of delivery corresponds to the product images.
Subject to changes, errors, and prior sale.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.