Murr MVK+MPNIO DI8 DI8 POF IRT 55254Murr
55254 MVK+MPNIO DI8 DI8 POF IRT
Murr MVK+MPNIO DI8 DI8 POF IRT 55254
Murr
55254 MVK+MPNIO DI8 DI8 POF IRT
FCA VB 부가세 별도
€450
제조 연도
2023
상태
신규
위치
Bielefeld 

기계 정보
가격 및 위치
FCA VB 부가세 별도
€450
- 위치:
- Frachtstraße 10 - 16, 33602 Bielefeld, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A9986858
- 업데이트:
- 마지막 업데이트: 26.03.2025
설명
Technical Data
INPUT
Sensor supply US 24 V DC (EN 61131-2), max. 200 mA (M12 female), short-circuit and overload protected
Type for 3-wire sensors or mechanical switches, PNP
GENERAL DATA
Mounting method 2-hole screw mounting
Temperature range 0...+55 °C (storage temperature -20...+70 °C)
Protection IP67
Dimensions H×W×D 56.2×63×225 mm
DIAGNOSTIC
Communication status via LED
Diagnostic via BUS per module and channel
Diagnostic via LED per module and channel
Actuator warning per channel via LED and BUS
Monitoring - under voltage yes
Monitoring - no voltage yes
Giodpfx Ajlu E Hmsqxot
Short-circuit and overload yes
Cable break per port
PROFINET
Specification V2.2, Conformance Class C (IRT)
Addressing DCP
FSU (Fast-Start-Up) max. 500 ms
PROFINET Netload Class III
MRP yes
Shared Device yes, for 2 controls
CONNECTIONS
Fieldbus Ethernet 10/100 Mbit/s; 2× SCRJ45 POF Push Pull
Sensor-system/actuator supply Push Pull Power connector, max. 12 A
I/O ports M12, 5-pole, A-coded
PARAMETERIZATION
PIN 4 Input
PIN 2 Input
3 pcs available 450€ / pc
INPUT
Sensor supply US 24 V DC (EN 61131-2), max. 200 mA (M12 female), short-circuit and overload protected
Type for 3-wire sensors or mechanical switches, PNP
GENERAL DATA
Mounting method 2-hole screw mounting
Temperature range 0...+55 °C (storage temperature -20...+70 °C)
Protection IP67
Dimensions H×W×D 56.2×63×225 mm
DIAGNOSTIC
Communication status via LED
Diagnostic via BUS per module and channel
Diagnostic via LED per module and channel
Actuator warning per channel via LED and BUS
Monitoring - under voltage yes
Monitoring - no voltage yes
Giodpfx Ajlu E Hmsqxot
Short-circuit and overload yes
Cable break per port
PROFINET
Specification V2.2, Conformance Class C (IRT)
Addressing DCP
FSU (Fast-Start-Up) max. 500 ms
PROFINET Netload Class III
MRP yes
Shared Device yes, for 2 controls
CONNECTIONS
Fieldbus Ethernet 10/100 Mbit/s; 2× SCRJ45 POF Push Pull
Sensor-system/actuator supply Push Pull Power connector, max. 12 A
I/O ports M12, 5-pole, A-coded
PARAMETERIZATION
PIN 4 Input
PIN 2 Input
3 pcs available 450€ / pc