분석 시스템 분자동 분석 장치NanoString
nCounter Sprint Profiler
분석 시스템 분자동 분석 장치
NanoString
nCounter Sprint Profiler
고정 가격 부가세 별도
€7,500
제조 연도
2015
상태
중고
위치
Wald 

기본 정보
가격 및 위치
고정 가격 부가세 별도
€7,500
- 위치:
- Hohenzollernstrasse 9, 88639 Wald, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A23202221
- 업데이트:
- 마지막 업데이트: 26.10.2026
설명
NanoString nCounter Sprint Profiler Analysis System
Technical Specifications
* Multiplex analysis: up to 800 targets simultaneously
* Sample throughput: up to 24 samples per day
* Sample capacity: 1–12 samples per run
* Hands-on time: approx. 10 minutes
* Analytical method: digital molecular counting using fluorescence-labeled reporter probes
* Sample preparation and analysis: integrated into a single device
* Sample material: total RNA, FFPE-derived RNA, cell lysates, and suitable lysed whole blood samples
* SPRINT cartridge reaction volume: 25–35 µl
* Dynamic measurement range: up to 6 × 10⁵ total counts
* Data export: digital count values, including as a CSV file
* Software: nSolver Analysis Software (check availability and license scope)
Device dimensions and weight
* Width: 107 cm
* Depth: 72 cm
* Height: 82 cm
Nodj Afcqqepfx Andslh
* Weight: approx. 95.25 kg
Technical description has been adopted.
You are welcome to visit us for a demonstration.
We can gladly arrange cost-effective shipping for you!
You will receive a proper invoice.
For foreign customers, a net invoice can also be issued. A valid VAT identification number is required.
Subject to prior sale.
Visit our shop and view our other offers.
The company names and trademarks mentioned are the property of their respective owners and are used solely for identification and description of the products.
Deviations from technical data and errors in the description of the article may occur and are subject to change.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Technical Specifications
* Multiplex analysis: up to 800 targets simultaneously
* Sample throughput: up to 24 samples per day
* Sample capacity: 1–12 samples per run
* Hands-on time: approx. 10 minutes
* Analytical method: digital molecular counting using fluorescence-labeled reporter probes
* Sample preparation and analysis: integrated into a single device
* Sample material: total RNA, FFPE-derived RNA, cell lysates, and suitable lysed whole blood samples
* SPRINT cartridge reaction volume: 25–35 µl
* Dynamic measurement range: up to 6 × 10⁵ total counts
* Data export: digital count values, including as a CSV file
* Software: nSolver Analysis Software (check availability and license scope)
Device dimensions and weight
* Width: 107 cm
* Depth: 72 cm
* Height: 82 cm
Nodj Afcqqepfx Andslh
* Weight: approx. 95.25 kg
Technical description has been adopted.
You are welcome to visit us for a demonstration.
We can gladly arrange cost-effective shipping for you!
You will receive a proper invoice.
For foreign customers, a net invoice can also be issued. A valid VAT identification number is required.
Subject to prior sale.
Visit our shop and view our other offers.
The company names and trademarks mentioned are the property of their respective owners and are used solely for identification and description of the products.
Deviations from technical data and errors in the description of the article may occur and are subject to change.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
최종 온라인: 지난주
등록일: 2013
143 온라인 광고
문의 보내기
전화기 & 팩스
+49 7578 ... 광고
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다