Prince Technologies PrinCe 560
Capillary Zone Electrophoresis System
Connections:
Power supply, HV control, Parallel connection A, Parallel connection B,
Serial connection A (RS232), Serial connection B (RS232).
Technical Data:
Injection method: Up to 650 min, in 0.01 min steps; Hydrodynamics: 180 - 250 mbar,
in 1 mbar steps, Electrokinetics: -30 to +30 kV, current and/or voltage.
Flow/Pressure range: 0 to +3000 mbar from DCI device.
Voltage range: -30 kV to +30 kV
Gkodpfeu Eb D Hsx Andsc
Current range: -200 µA to +200 µA
Ramp: Programmable voltage or current ramp.
Polarity reversal: Programmable before and during sample run.
Autosampler: Position carousel for 30/48 sample and buffer vials. Variable vial size, including Eppendorf micro centrifuge tubes.
Buffer volume: Max. 4 ml
Sample volume: Minimum 10 µl, max 4 ml.
Temperature control: Samples and buffer 4 °C to 40 °C.
Capillary temperature: 5 °C to below 60 °C.
Detector: Allows the use of: UV/Vis, fluorescence, diode array, LIF, conductivity, electrochemical, and MS.
Year of manufacture: 2004
Model: PrinCe 560 0500.022/CR
S/N: 50-14-05-3-23
Dimensions: 50x50x54 cm
Weight: 35 kg
Without functional test.
More items – new and used – can be found in our shop!
International shipping costs on request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Capillary Zone Electrophoresis System
Connections:
Power supply, HV control, Parallel connection A, Parallel connection B,
Serial connection A (RS232), Serial connection B (RS232).
Technical Data:
Injection method: Up to 650 min, in 0.01 min steps; Hydrodynamics: 180 - 250 mbar,
in 1 mbar steps, Electrokinetics: -30 to +30 kV, current and/or voltage.
Flow/Pressure range: 0 to +3000 mbar from DCI device.
Voltage range: -30 kV to +30 kV
Gkodpfeu Eb D Hsx Andsc
Current range: -200 µA to +200 µA
Ramp: Programmable voltage or current ramp.
Polarity reversal: Programmable before and during sample run.
Autosampler: Position carousel for 30/48 sample and buffer vials. Variable vial size, including Eppendorf micro centrifuge tubes.
Buffer volume: Max. 4 ml
Sample volume: Minimum 10 µl, max 4 ml.
Temperature control: Samples and buffer 4 °C to 40 °C.
Capillary temperature: 5 °C to below 60 °C.
Detector: Allows the use of: UV/Vis, fluorescence, diode array, LIF, conductivity, electrochemical, and MS.
Year of manufacture: 2004
Model: PrinCe 560 0500.022/CR
S/N: 50-14-05-3-23
Dimensions: 50x50x54 cm
Weight: 35 kg
Without functional test.