성형Schmitz Walzmaschine
EA2 - 125/200
성형
Schmitz Walzmaschine
EA2 - 125/200
EXW 고정 가격 부가세 별도
€5,000
제조 연도
1959
상태
중고
위치
Schwäbisch Gmünd 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
EXW 고정 가격 부가세 별도
€5,000
- 위치:
- Katharinenstraße 13-17, 73525 17, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A21666753
- 업데이트:
- 마지막 업데이트: 08.04.2026
설명
The two-roll precision rolling machine applies a pressure of 26,000 kg and features a roller core diameter of 125 mm as well as a total roller body length of 200 mm. The effective strip width is 175 mm, within which a uniform distribution is ensured. The commission number is 59024, which allows the manufacturer to retrieve the exact construction drawings.
After some time, the machine stops operating. It is suspected that the electrician should take the following into consideration:
• Connection type: Three-phase current 380V/400V (3 phases + neutral + earth).
• Power socket: Due to the current intensity (22.8 A), a CEE 32A socket (red industrial socket) is required.
• Protection: The motor must be protected with slow-blow fuses (e.g., type C circuit breakers or Neozed fuses) to handle the high inrush current. A 32A (three-pole) protection is recommended.
• Motor protection: A motor protection switch set to the rated current (here 22.8 A) is absolutely necessary to protect the motor from overload.
Important note: The specifications (71.5 rpm, 5 Hz) indicate either a very slow-running special motor or a motor operated via a frequency inverter. Commissioning should only be carried out by a qualified electrician.
Fodpfsyzh Tbox Abnjga
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
After some time, the machine stops operating. It is suspected that the electrician should take the following into consideration:
• Connection type: Three-phase current 380V/400V (3 phases + neutral + earth).
• Power socket: Due to the current intensity (22.8 A), a CEE 32A socket (red industrial socket) is required.
• Protection: The motor must be protected with slow-blow fuses (e.g., type C circuit breakers or Neozed fuses) to handle the high inrush current. A 32A (three-pole) protection is recommended.
• Motor protection: A motor protection switch set to the rated current (here 22.8 A) is absolutely necessary to protect the motor from overload.
Important note: The specifications (71.5 rpm, 5 Hz) indicate either a very slow-running special motor or a motor operated via a frequency inverter. Commissioning should only be carried out by a qualified electrician.
Fodpfsyzh Tbox Abnjga
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
등록일: 2026
10 온라인 광고
문의 보내기
전화기 & 팩스
+49 7171 ... 광고
귀하의 광고가 성공적으로 삭제되었습니다