온도 교정기 SIKA TP 3M 165 ESIKA
Ölbad TP3M165E
온도 교정기 SIKA TP 3M 165 E
SIKA
Ölbad TP3M165E
EXW 고정 가격 부가세 별도
€5,000
제조 연도
2015
상태
중고
위치
Offenburg 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
EXW 고정 가격 부가세 별도
€5,000
- 위치:
- Im Drachenacker 7a, 77656 Offenburg, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A21432102
- 업데이트:
- 마지막 업데이트: 11.03.2026
설명
For sale is a used temperature calibrator from the manufacturer Sika based in Kaufungen, Germany (Made in Germany).
The device was only used as a micro bath/oil bath in our calibration laboratory and is no longer needed.
No additional accessories are included; however, these can be purchased from the manufacturer. (Other measuring equipment shown in the pictures is not included in the offer.)
Temperature range: -30°C to 165°C
Manufacturer specifications:
Description:
Whether for on-site use in the workshop, in the measurement and test room, or in the laboratory, SIKA temperature calibrators are utilized anywhere. A wide range of industries with diverse applications are covered.
• Assembly, commissioning
• Manufacturing, production
• Maintenance, service
• Quality assurance, test equipment monitoring
• Repair
Micro bath function:
Kledpfoyrb Hhox Adiop
When temperature sensors with unusual shapes and sizes need to be tested, using calibration fluids offers advantages. The unit under test is placed directly in the fluid, ensuring a direct heat transfer between calibrator and device without insulating air gaps. The calibration fluid, such as silicone oil, is selected according to the required calibration temperature. The stepless regulation of the magnetic stirrer, combined with the removable sensor basket, ensures thorough mixing of the calibration liquid and creates a large measurement zone. Furthermore, the sensor basket allows undisturbed stirring operation and protects the tank bottom.
Dry block function:
The dry block function is designed to allow simple temperature calibration in laboratory and field applications. Optimal thermal coupling between the block and the device under test is achieved using the correct sleeve. Ideally, the bore in the sleeve should be 0.5 mm larger in diameter than the outside diameter of the sensor. The sleeve enables calibration of almost all straight temperature sensors with different lengths and diameters. The dry block covers the entire temperature range without the need to change the calibration medium. The user does not have to consider viscosities, flash points, or outgassing.
Blackbody function:
For the calibration of IR pyrometers or thermal imaging cameras, a patented infrared calibration sleeve is used. The special surface structure and asymmetric shapes create a “black cavity radiator” with an emissivity factor of 0.9994, preventing the reflection of stray radiation and emitting the desired temperature in an ideal manner. The pyrometer is simply held at the prescribed distance above the measurement opening, allowing the desired measurement spot on the base to be targeted for calibration. Direct mounting of a tripod is possible.
Surface temperature function:
Surface temperature sensors are calibrated using special sleeves that are placed vertically with the required contact force. By switching the calibrator controller to the external reference sensor, the best possible temperature reference point on the sleeve surface is achieved.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
The device was only used as a micro bath/oil bath in our calibration laboratory and is no longer needed.
No additional accessories are included; however, these can be purchased from the manufacturer. (Other measuring equipment shown in the pictures is not included in the offer.)
Temperature range: -30°C to 165°C
Manufacturer specifications:
Description:
Whether for on-site use in the workshop, in the measurement and test room, or in the laboratory, SIKA temperature calibrators are utilized anywhere. A wide range of industries with diverse applications are covered.
• Assembly, commissioning
• Manufacturing, production
• Maintenance, service
• Quality assurance, test equipment monitoring
• Repair
Micro bath function:
Kledpfoyrb Hhox Adiop
When temperature sensors with unusual shapes and sizes need to be tested, using calibration fluids offers advantages. The unit under test is placed directly in the fluid, ensuring a direct heat transfer between calibrator and device without insulating air gaps. The calibration fluid, such as silicone oil, is selected according to the required calibration temperature. The stepless regulation of the magnetic stirrer, combined with the removable sensor basket, ensures thorough mixing of the calibration liquid and creates a large measurement zone. Furthermore, the sensor basket allows undisturbed stirring operation and protects the tank bottom.
Dry block function:
The dry block function is designed to allow simple temperature calibration in laboratory and field applications. Optimal thermal coupling between the block and the device under test is achieved using the correct sleeve. Ideally, the bore in the sleeve should be 0.5 mm larger in diameter than the outside diameter of the sensor. The sleeve enables calibration of almost all straight temperature sensors with different lengths and diameters. The dry block covers the entire temperature range without the need to change the calibration medium. The user does not have to consider viscosities, flash points, or outgassing.
Blackbody function:
For the calibration of IR pyrometers or thermal imaging cameras, a patented infrared calibration sleeve is used. The special surface structure and asymmetric shapes create a “black cavity radiator” with an emissivity factor of 0.9994, preventing the reflection of stray radiation and emitting the desired temperature in an ideal manner. The pyrometer is simply held at the prescribed distance above the measurement opening, allowing the desired measurement spot on the base to be targeted for calibration. Direct mounting of a tripod is possible.
Surface temperature function:
Surface temperature sensors are calibrated using special sleeves that are placed vertically with the required contact force. By switching the calibrator controller to the external reference sensor, the best possible temperature reference point on the sleeve surface is achieved.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
등록일: 2023
1 온라인 광고
문의 보내기
전화기 & 팩스
+49 170 4... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
독일
8,579 km
CNC 선반
Style650/3000
Style650/3000
소형 광고
Borken
8,707 km
와이어 및 밴드 벤딩 자동기, 프레스 번호 15
Schroeder & BauerWB 32-1
Schroeder & BauerWB 32-1
소형 광고
Tönisvorst
8,766 km
누출 검출기
Airflow UKLM 1
Airflow UKLM 1
소형 광고
Oława
8,229 km
도구 사전 설정 장치
OCS ALFA -SYSSARA-SET 33 SWift
OCS ALFA -SYSSARA-SET 33 SWift
소형 광고
Wiefelstede
8,537 km
개인 접지 테스트 장치
WarmbierSafety Pips 7100.181
WarmbierSafety Pips 7100.181
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다