2대의 AI AS 1310 오토샘플러 포함Thermo Fisher Scientific
Flash 2000 CHNS O Analyzer
2대의 AI AS 1310 오토샘플러 포함
Thermo Fisher Scientific
Flash 2000 CHNS O Analyzer
고정 가격 부가세 별도
€6,500
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
- 기계 명칭:
- 2대의 AI AS 1310 오토샘플러 포함
- 상태:
- 매우 좋음 (중고)
가격 및 위치
고정 가격 부가세 별도
€6,500
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A21755313
- 참조 번호:
- 25147
- 업데이트:
- 마지막 업데이트: 20.04.2026
설명
Thermo Fisher Scientific Flash 2000 CHNS O Analyzer with 2 x AI AS 1310 Autosamplers
For sale is a used Thermo Fisher Scientific Flash 2000 elemental analyzer. The unit is equipped with two AI AS 1310 autosamplers and is designed for automated laboratory operations.
This system is used for elemental analysis in laboratory settings. Sample introduction is managed via the installed autosamplers, allowing for continuous and automated operation.
Equipment and Configuration
- Thermo Fisher Scientific Flash 2000
- CHNS O Analyzer
- 2 x AI AS 1310 Autosamplers
- Front display with status indicators for operational states
- Gas connections for He and O2
- RS232 interface and additional device interfaces
- Connections for autosamplers and optional modules
- Power supply: 230 V
- Accessories and parts as shown in the images
Technical Data
Manufacturer: Thermo Fisher Scientific
Model: Flash 2000
Device type: Elemental analyzer
Voltage: 230 V AC
Frequency: 50/60 Hz
Fuses: 2 x 6 A
Power consumption: 1400 VA
Nlsdpfxsy D Sqvs Akfoa
Autosamplers
Model: AI AS 1310
Supply voltage: 24 V DC
Power: 46 W per unit
Serial numbers: 420126446 and 420126487
Dimensions
Main unit width: approx. 55 to 60 cm
Depth: approx. 55 to 65 cm
Height: approx. 50 to 60 cm
Total width with 2 autosamplers: approx. 100 to 120 cm
Weight
Main unit: approx. 45 to 60 kg
Each autosampler: approx. 8 to 12 kg
Total: approx. 60 to 80 kg
Condition
Used, with age- and usage-related signs of wear. Condition as shown in the images.
Scope of delivery
- Flash 2000 Analyzer
- 2 x Autosamplers
- Accessories and cables as shown
Notes
- The table shown in the photos is not included in the sale
- All information is taken from the nameplate or the device shown
- Subject to errors and prior sale
- We are happy to answer any questions you may have.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
For sale is a used Thermo Fisher Scientific Flash 2000 elemental analyzer. The unit is equipped with two AI AS 1310 autosamplers and is designed for automated laboratory operations.
This system is used for elemental analysis in laboratory settings. Sample introduction is managed via the installed autosamplers, allowing for continuous and automated operation.
Equipment and Configuration
- Thermo Fisher Scientific Flash 2000
- CHNS O Analyzer
- 2 x AI AS 1310 Autosamplers
- Front display with status indicators for operational states
- Gas connections for He and O2
- RS232 interface and additional device interfaces
- Connections for autosamplers and optional modules
- Power supply: 230 V
- Accessories and parts as shown in the images
Technical Data
Manufacturer: Thermo Fisher Scientific
Model: Flash 2000
Device type: Elemental analyzer
Voltage: 230 V AC
Frequency: 50/60 Hz
Fuses: 2 x 6 A
Power consumption: 1400 VA
Nlsdpfxsy D Sqvs Akfoa
Autosamplers
Model: AI AS 1310
Supply voltage: 24 V DC
Power: 46 W per unit
Serial numbers: 420126446 and 420126487
Dimensions
Main unit width: approx. 55 to 60 cm
Depth: approx. 55 to 65 cm
Height: approx. 50 to 60 cm
Total width with 2 autosamplers: approx. 100 to 120 cm
Weight
Main unit: approx. 45 to 60 kg
Each autosampler: approx. 8 to 12 kg
Total: approx. 60 to 80 kg
Condition
Used, with age- and usage-related signs of wear. Condition as shown in the images.
Scope of delivery
- Flash 2000 Analyzer
- 2 x Autosamplers
- Accessories and cables as shown
Notes
- The table shown in the photos is not included in the sale
- All information is taken from the nameplate or the device shown
- Subject to errors and prior sale
- We are happy to answer any questions you may have.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다



































