워크인 기후 시뮬레이션 셀TIRA
KB 127 TCZ 4022 S -2K -40 bis +140°C
워크인 기후 시뮬레이션 셀
TIRA
KB 127 TCZ 4022 S -2K -40 bis +140°C
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A18478886
- 참조 번호:
- 23515
- 업데이트:
- 마지막 업데이트: 12.03.2026
설명
TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
Kwjdpfx Aovx S Hhjdisw
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
Kwjdpfx Aovx S Hhjdisw
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Pfalzgrafenweiler
8,879 km
실험실 프레스
JoosLAP-M 30
JoosLAP-M 30
소형 광고
Olsztyn
7,867 km
실험실 장비 - 세트
Shimadzu, Wyposażenie laboratorium
Shimadzu, Wyposażenie laboratorium
소형 광고
Matelica (MC)
9,026 km
밀링 머신 - 포털
PARPASDIAMOND LINEAR30
PARPASDIAMOND LINEAR30
소형 광고
Skarżysko-Kamienna
8,015 km
전기 중합로
Romer PolandSL - 2020
Romer PolandSL - 2020
소형 광고
Enschede
8,676 km
튜브 레이저 절단기
Bodor K2
Bodor K2
소형 광고
Wuppertal
8,739 km
스포팅 프레스
HESSMERT160 EST
HESSMERT160 EST
소형 광고
Zuchwil
9,036 km
레토르트 열처리로
MUT360/400-1150
MUT360/400-1150
소형 광고
Gelnhausen
8,722 km
파이퍼 베큠 Okta 6000
Pfeiffer VacuumOkta 6000
Pfeiffer VacuumOkta 6000
소형 광고
Möckmühl
8,779 km
열성형 기계
IlligUA 155 G Solo/ BE
IlligUA 155 G Solo/ BE
소형 광고
Möckmühl
8,779 km
열성형 기계
IlligUA 200 G Solo/BE
IlligUA 200 G Solo/BE
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다