TIRA 기후 챔버 TCC 7120 -75°C / +180°C, 습도 포함TIRA
Klimakammer
TIRA 기후 챔버 TCC 7120 -75°C / +180°C, 습도 포함
TIRA
Klimakammer
상태
중고
위치
Borken 

기본 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A22242797
- 참조 번호:
- 24604
- 업데이트:
- 마지막 업데이트: 15.10.2026
설명
TIRA
Type: TCC 7120
Hfjdozh Htqopfx Adcon
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the test chamber) ±0.1°C ... ±0.3°C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% to ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x W x H) 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf 50 kg
Maximum floor load of the test chamber 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Type: TCC 7120
Hfjdozh Htqopfx Adcon
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the test chamber) ±0.1°C ... ±0.3°C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% to ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x W x H) 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf 50 kg
Maximum floor load of the test chamber 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다