습도 조절형 기후 챔버, 190리터Vötsch
VC³ 4018 -40/+180°C
습도 조절형 기후 챔버, 190리터
Vötsch
VC³ 4018 -40/+180°C
상태
중고
위치
Borken 

기계 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A22111738
- 참조 번호:
- 25249
- 업데이트:
- 마지막 업데이트: 12.06.2026
설명
Vötsch VC³ 4018 Climate Test Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 4018
Machine Type: Climate Test Chamber / Temperature Test Chamber
Design: Air-cooled
Test Chamber Volume: approx. 190 liters
For sale is a used climate test chamber from the manufacturer Vötsch. The VC³ 4018 is suitable for temperature and climate tests, environmental simulation, material testing, electronics testing, quality assurance, as well as research and development applications.
Technical Data:
Temperature Range: -40 °C to +180 °C
Temperature Change Rate (Heating): approx. 4 K/min
Temperature Change Rate (Cooling): approx. 4 K/min
Max. Heat Compensation in Temperature Operation: approx. 2300 W
Temperature Deviation (Time): ± 0.1 to ± 0.5 K
Temperature Homogeneity (Spatial): ± 0.5 to ± 1.5 K
Climate Range (Temperature): +10 °C to +95 °C
Dew Point Range: -3 °C to +94 °C
Humidity Range: 10 to 98 % RH
Temperature Deviation (Time) in Climate Operation: ± 0.1 to ± 0.3 K
Temperature Homogeneity (Spatial) in Climate Operation: ± 0.5 to ± 1 K
Humidity Deviation (Time): ± 1 to ± 3 % RH
Heat Compensation in Climate Operation: approx. 400 W
Test Chamber Dimensions (approx.): 580 x 450 x 750 mm (W x D x H)
Housing Dimensions (approx.): 870 x 1550 x 1800 mm (W x D x H)
Weight (approx.): 470 kg
Refrigerant: R404A
Refrigerant Quantity: 2.50 kg
ND max.: 22.5 bar g
HD max.: 25 bar g
Mains Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 4.1 kW
Rated Current: 14 A
Test Chamber Lighting: Halogen, 2 x 24 V / 50 W
Equipment
Touch Panel Operation
Kedpfxozc Ht Ij Aikodn
Viewing Window in the Door
Stainless Steel Test Chamber
Test Chamber Lighting
Side Pass-Throughs
Shelves / Interior Fittings as Shown in Pictures
Documentation / Operating Manual
Further Accessories as Shown in Pictures
Condition
Used
Optical Condition as Shown in Pictures
Scope of Delivery as Shown
Inspection Possible by Appointment
Safety Note
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Due to the size and weight, shipping by freight forwarder is recommended.
Scope of delivery as shown.
Subject to change and errors in the technical data, as well as prior sale.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 4018
Machine Type: Climate Test Chamber / Temperature Test Chamber
Design: Air-cooled
Test Chamber Volume: approx. 190 liters
For sale is a used climate test chamber from the manufacturer Vötsch. The VC³ 4018 is suitable for temperature and climate tests, environmental simulation, material testing, electronics testing, quality assurance, as well as research and development applications.
Technical Data:
Temperature Range: -40 °C to +180 °C
Temperature Change Rate (Heating): approx. 4 K/min
Temperature Change Rate (Cooling): approx. 4 K/min
Max. Heat Compensation in Temperature Operation: approx. 2300 W
Temperature Deviation (Time): ± 0.1 to ± 0.5 K
Temperature Homogeneity (Spatial): ± 0.5 to ± 1.5 K
Climate Range (Temperature): +10 °C to +95 °C
Dew Point Range: -3 °C to +94 °C
Humidity Range: 10 to 98 % RH
Temperature Deviation (Time) in Climate Operation: ± 0.1 to ± 0.3 K
Temperature Homogeneity (Spatial) in Climate Operation: ± 0.5 to ± 1 K
Humidity Deviation (Time): ± 1 to ± 3 % RH
Heat Compensation in Climate Operation: approx. 400 W
Test Chamber Dimensions (approx.): 580 x 450 x 750 mm (W x D x H)
Housing Dimensions (approx.): 870 x 1550 x 1800 mm (W x D x H)
Weight (approx.): 470 kg
Refrigerant: R404A
Refrigerant Quantity: 2.50 kg
ND max.: 22.5 bar g
HD max.: 25 bar g
Mains Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 4.1 kW
Rated Current: 14 A
Test Chamber Lighting: Halogen, 2 x 24 V / 50 W
Equipment
Touch Panel Operation
Kedpfxozc Ht Ij Aikodn
Viewing Window in the Door
Stainless Steel Test Chamber
Test Chamber Lighting
Side Pass-Throughs
Shelves / Interior Fittings as Shown in Pictures
Documentation / Operating Manual
Further Accessories as Shown in Pictures
Condition
Used
Optical Condition as Shown in Pictures
Scope of Delivery as Shown
Inspection Possible by Appointment
Safety Note
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Due to the size and weight, shipping by freight forwarder is recommended.
Scope of delivery as shown.
Subject to change and errors in the technical data, as well as prior sale.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Borken
8,705 km
48V 벨트 스타터 발전기 테스트 벤치
KübrichKomponentenprüfstand
KübrichKomponentenprüfstand
소형 광고
Hessisch Lichtenau
8,614 km
외부 순환 욕조, 순환 온도 조절기, 온도 욕조, 순환 욕조, 순환 욕조, 오일 욕조, 오일 욕조, 물
BROOKFIELDTC-102D
BROOKFIELDTC-102D
소형 광고
Borken
8,705 km
온도 캐비닛 990리터
WeissWT3-1000/40 -40°C bis +180°C
WeissWT3-1000/40 -40°C bis +180°C
소형 광고
Borken
8,705 km
온도 챔버
WEISSWT11-1000/70/5
WEISSWT11-1000/70/5
소형 광고
Borken
8,705 km
습도 190리터의 기후 테스트 챔버
VötschVC 7018 -70 bis 180°C
VötschVC 7018 -70 bis 180°C
소형 광고
Borken
8,705 km
기후 테스트 챔버 온도 -70°C ~ +180°C
Vötsch 190 LiterVCS 7018-5
Vötsch 190 LiterVCS 7018-5
소형 광고
Borken
8,705 km
습도가 있는 기후 테스트 챔버
VötschVC³ 0100 0°C bis + 90°C
VötschVC³ 0100 0°C bis + 90°C
소형 광고
Janville
9,246 km
인큐베이터 / 건조 오븐
MemmertB 30
MemmertB 30
소형 광고
Borken
8,705 km
기후 시험 챔버 190리터
VötschVC³ 7018 -70°C bis +180°C
VötschVC³ 7018 -70°C bis +180°C
소형 광고
Borken
8,705 km
온도 테스트 챔버
VötschVTS 7034-5
VötschVTS 7034-5
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다



















































































































