기후 시험 챔버 190리터Vötsch
VC³ 7018 -70°C bis +180°C
기후 시험 챔버 190리터
Vötsch
VC³ 7018 -70°C bis +180°C
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A20748272
- 참조 번호:
- 24927
- 업데이트:
- 마지막 업데이트: 12.12.2025
설명
Vötsch
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Lodpex Hg Uujfx Afrsri
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Lodpex Hg Uujfx Afrsri
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Balaguer
9,842 km
용접기
KEMPPIPRO 3000
KEMPPIPRO 3000
소형 광고
Auenwald
8,797 km
측정 시스템
ZEISSPRISMO 16
ZEISSPRISMO 16
소형 광고
독일
8,462 km
용접 시스템
KEMPPIPro MIG 500
KEMPPIPro MIG 500
소형 광고
Borken
8,705 km
190L 온도 테스트 캐비닛
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
소형 광고
Auenwald
8,797 km
좌표 측정기
ZEISSPrismo 10 - 12.24.10 mit REVO2
ZEISSPrismo 10 - 12.24.10 mit REVO2
소형 광고
Borken
8,705 km
습도가 있는 기후 테스트 캐비닛
WeissSB2/500/80 -75°C bis +180°C
WeissSB2/500/80 -75°C bis +180°C
소형 광고
Denkendorf/Bitz
8,689 km
좌표 측정 기계
ZeissSMM-C Duplex DSE
ZeissSMM-C Duplex DSE
소형 광고
Weilheim an der Teck
8,820 km
ACCURA II MASS 16/42/15
ZeissACCURA II MASS 16/42/15
ZeissACCURA II MASS 16/42/15
소형 광고
Kaufungen
8,613 km
용접 기계
OTC DaihenM 380 S
OTC DaihenM 380 S
소형 광고
Borken
8,705 km
진자 충격 시험기 5.5J
Zwick RoellHIT5.5P
Zwick RoellHIT5.5P
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다