기후 테스트 챔버 -10°C ~ +90°CVötsch
VC 0018
기후 테스트 챔버 -10°C ~ +90°C
Vötsch
VC 0018
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A19843535
- 참조 번호:
- 24768
- 업데이트:
- 마지막 업데이트: 26.08.2025
설명
Vötsch
Model: VC 0018
Air-cooled climate test chamber
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
Housing dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test chamber volume: approx. 190 liters
Performance data for temperature tests:
Temperature range: -10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.5 K
spatially ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 0.6 K/min.
Cooling: 0.3 K/min.
Heat compensation in the range +20 °C to +50 °C: 200 W
Calibration values: +4 °C and +90 °C
Performance data for climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.3 K
spatially ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Electrical connection:
Rated voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.7 kW
Itjdpfx Adew Swrto Her
Rated current: 9.5 A
(Neutral conductor plug: loaded)
Schuko approx. connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R-134A
Buyer Information for Your Safety!
The following procedures are carried out on our climate chambers prior to sale:
1. Function check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
Technical specifications and information subject to change and errors!
Feel free to call us with any further questions.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Model: VC 0018
Air-cooled climate test chamber
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
Housing dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test chamber volume: approx. 190 liters
Performance data for temperature tests:
Temperature range: -10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.5 K
spatially ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 0.6 K/min.
Cooling: 0.3 K/min.
Heat compensation in the range +20 °C to +50 °C: 200 W
Calibration values: +4 °C and +90 °C
Performance data for climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.3 K
spatially ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Electrical connection:
Rated voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.7 kW
Itjdpfx Adew Swrto Her
Rated current: 9.5 A
(Neutral conductor plug: loaded)
Schuko approx. connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R-134A
Buyer Information for Your Safety!
The following procedures are carried out on our climate chambers prior to sale:
1. Function check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
Technical specifications and information subject to change and errors!
Feel free to call us with any further questions.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고