온도 테스트 챔버 335리터Vötsch
VTS 7034-5 -70°C bis +180°C
온도 테스트 챔버 335리터
Vötsch
VTS 7034-5 -70°C bis +180°C
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A7823351
- 참조 번호:
- 23261
- 업데이트:
- 마지막 업데이트: 15.11.2024
설명
Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Type: VTS 7034-5
Lhodpfx Ajir D U Djdiod
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Type: VTS 7034-5
Lhodpfx Ajir D U Djdiod
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Borken
8,705 km
온도 테스트 챔버 335리터
Vötsch-70°C bis +180°C VTS 7034-5
Vötsch-70°C bis +180°C VTS 7034-5
소형 광고
Borken
8,705 km
디지털 주사 전자 현미경
ZeissDSM 962
ZeissDSM 962
소형 광고
Borken
8,705 km
온도 테스트 챔버 335리터
Vötsch-70°C bis +180°C VTS 7034-5
Vötsch-70°C bis +180°C VTS 7034-5
소형 광고
Umraniye
8,122 km
롤 성형 라인
BOSPORASACOUSTIC SOUND BARRIER PANEL
BOSPORASACOUSTIC SOUND BARRIER PANEL
소형 광고
Velžys
7,539 km
유리 틸팅 테이블
TRIULZI-IGTilting table
TRIULZI-IGTilting table
소형 광고
Güglingen
8,815 km
낮은 GWP 칠러 R32, R454B, R513A
HitemaENR SBS
HitemaENR SBS
소형 광고
Veghel
8,791 km
금속 절단기 1325 E 기본
Wattsan1325 E
Wattsan1325 E
소형 광고
Saerbeck
8,642 km
5 축 레이저 절단기 | 3D
Durma |HD-FA
Durma |HD-FA
소형 광고
Dinkelsbühl
8,743 km
탭핑센터
CMAFTC 3015
CMAFTC 3015
소형 광고
Borken
8,705 km
190L 온도 테스트 캐비닛
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다