설명
Core Drive Specifications
NXI: NX Inverter Unit. It is designed to be fed by a shared, common DC bus arrangement rather than direct AC mains input.
0072: 72 Amps Nominal Current Rating.Low Overload (Pumps/Fans): Continuous maximum output of 72 A.
High Overload (Heavy Duty): Continuous maximum output of 61 A.
5: Mains Voltage Class. Rated for 380 V to 500 V AC grid systems (which corresponds to a DC bus voltage range of 465 V to 800 V DC).
A: Includes the Standard Alpha-numeric Control Keypad.
5: IP54 (NEMA 12) Enclosure Class. This offers strong, dust-protected, splash-resistant defense for hash operational environments.
Bjdey Ud Afspfx Adhjlp
T: Standard EMC Emission Level adhering to the IEC61800-3 specification for IT networks.
0: No integrated brake chopper.
C: Physical frame generation / module sizing designated as Frame FR7.
Internal Hardware & Control Boards (SVA1AF00000)
The suffix code segment details the exact internal logic, system software, and factory expansion board routing layout:
S: Air-cooled design system.
V: Internal coating option. It features varnished/coated circuit boards for moisture and corrosive air resilience.
A: Standard Vacon System Interface architecture setup.
1AF00000: This sequence identifies the specific hardware configuration across the control expansion slots (A, B, C, D, and E):A1: OPT-A1 Basic I/O Board installed in Slot A. It provides 6 digital inputs, 1 digital output, 2 analog inputs, 1 analog output, +10V reference voltage, and a +24V auxiliary supply.
AF: OPT-AF Dual Relay Output Board installed in Slot B. It provides 2 programmable changeover relay outputs (NO/NC configuration).
00000: Slots C, D, and E are left empty from the factory, giving you expansion headroom for fieldbus communications (such as Profinet or EtherCAT) if needed
Brand new never used. Please check out our other listings as well.
NXI: NX Inverter Unit. It is designed to be fed by a shared, common DC bus arrangement rather than direct AC mains input.
0072: 72 Amps Nominal Current Rating.Low Overload (Pumps/Fans): Continuous maximum output of 72 A.
High Overload (Heavy Duty): Continuous maximum output of 61 A.
5: Mains Voltage Class. Rated for 380 V to 500 V AC grid systems (which corresponds to a DC bus voltage range of 465 V to 800 V DC).
A: Includes the Standard Alpha-numeric Control Keypad.
5: IP54 (NEMA 12) Enclosure Class. This offers strong, dust-protected, splash-resistant defense for hash operational environments.
Bjdey Ud Afspfx Adhjlp
T: Standard EMC Emission Level adhering to the IEC61800-3 specification for IT networks.
0: No integrated brake chopper.
C: Physical frame generation / module sizing designated as Frame FR7.
Internal Hardware & Control Boards (SVA1AF00000)
The suffix code segment details the exact internal logic, system software, and factory expansion board routing layout:
S: Air-cooled design system.
V: Internal coating option. It features varnished/coated circuit boards for moisture and corrosive air resilience.
A: Standard Vacon System Interface architecture setup.
1AF00000: This sequence identifies the specific hardware configuration across the control expansion slots (A, B, C, D, and E):A1: OPT-A1 Basic I/O Board installed in Slot A. It provides 6 digital inputs, 1 digital output, 2 analog inputs, 1 analog output, +10V reference voltage, and a +24V auxiliary supply.
AF: OPT-AF Dual Relay Output Board installed in Slot B. It provides 2 programmable changeover relay outputs (NO/NC configuration).
00000: Slots C, D, and E are left empty from the factory, giving you expansion headroom for fieldbus communications (such as Profinet or EtherCAT) if needed