설명
HPLC Waters
The system consists of these modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
Lasdpfovcnpajx Adgjc
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
The system consists of these modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
Lasdpfovcnpajx Adgjc
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Wald
8,892 km
분광기
Varian640-IR FT-IR
Varian640-IR FT-IR
소형 광고
Krotoszyn
8,170 km
산업용 증기 보일러
Loos Bosch GroupU-ND 800
Loos Bosch GroupU-ND 800
소형 광고
Ybbs an der Donau
8,546 km
FTIR 분광기 - NICOLET IS20
ThermoFisher ScientificNICOLET IS20
ThermoFisher ScientificNICOLET IS20
소형 광고
Hadımköy
8,122 km
회전 터널식 세탁기
INTERSONIKRT-540
INTERSONIKRT-540
소형 광고
Erlangen
8,671 km
건조기가 있는 7.5kW 스크류 압축기
KaeserSM 13 T
KaeserSM 13 T
소형 광고
Dn10 4Es
8,930 km
단발 예금자
AFTmini depositor
AFTmini depositor
소형 광고
Łabuńki Pierwsze
7,902 km
스크류 압축기
Atlas CopcoG11FF
Atlas CopcoG11FF
소형 광고
Velen
8,701 km
플라즈마 절단기
HBMCUT 60
HBMCUT 60
소형 광고
Malawa
8,016 km
제과용 오븐 + 적재 시스템
MiweTHERMO EXPRESS + ATHLET
MiweTHERMO EXPRESS + ATHLET
소형 광고
Bitburg
8,872 km
냉동식 건조기를 갖춘 스크류 압축기
Aircraft / FiniA-K-Max 7,5-10-270 K (IE3)
Aircraft / FiniA-K-Max 7,5-10-270 K (IE3)
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다