기후 시험 챔버, 온도: -70~180°CWeiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
기후 시험 챔버, 온도: -70~180°C
Weiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
상태
중고
위치
Borken 

기계 정보
- 기계 명칭:
- 기후 시험 챔버, 온도: -70~180°C
- 상태:
- 매우 좋음 (중고)
가격 및 위치
- 위치:
- Einsteinstraße 8a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A22241172
- 참조 번호:
- 20744
- 업데이트:
- 마지막 업데이트: 01.07.2026
설명
Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
Gbodpszh D Ryefx Afqep
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold/Heat operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98 % RH
Temperature change per unit of time:
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse (on customer's side): 32 A, slow-blow
Permissible weight of test specimens:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
Gbodpszh D Ryefx Afqep
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold/Heat operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98 % RH
Temperature change per unit of time:
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse (on customer's side): 32 A, slow-blow
Permissible weight of test specimens:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.