Weiss ShockEvent D/210/a/V1 수냉식 -65 ~ +200°C, 210리터Weiss
Vötsch Schocktestkammer
Weiss ShockEvent D/210/a/V1 수냉식 -65 ~ +200°C, 210리터
Weiss
Vötsch Schocktestkammer
상태
중고
위치
Borken 

기본 정보
- 제조업체:
- Weiss
- 상태:
- 중고
가격 및 위치
- 위치:
- Borken, 독일

전화하기
제안 세부 정보
- 광고 ID:
- A22956316
- 참조 번호:
- 25722
- 업데이트:
- 마지막 업데이트: 14.10.2026
설명
Weiss
Weiss ShockEvent D/210/a/V1
Type of equipment: Temperature-controlled shock testing chamber
Testing principle: Stationary test chamber with supply of warm, cold, and ambient air via flaps
Test chamber volume: approx. 210 liters
Usable test chamber width / height according to installation plan: 700 / 500 mm
Installation dimensions according to installation plan (W × D × H): approx. 1,480 × 1,670 × 1,967 mm, plus space for attachments
Weight: approx. 1,350 kg
Temperature range, warm chamber: +50 to +225 °C
Temperature range, test chamber, warm phase: +50 to +200 °C
Temperature range, test chamber, cold phase: −65 to 0 °C
Temperature range, cold chamber: −70 to 0 °C
Heating rate: 18 K/min, i.e. 18 °C
Cooling rate: 2 K/min, i.e. 2 °C
Temperature deviation over time: ±0.3 to ±0.5 K in steady state
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Heat compensation, cold phase: max. 6,000 W at −20 °C
Heat compensation, warm phase: 0 W
Maximum load, test chamber floor: 100 kg, evenly distributed
Maximum number of insert baskets: 7 pieces
Maximum load per insert basket: 7.5 kg
Maximum total load of insert baskets: 50 kg
Distance between insert baskets: 50 mm
Operation: WEBPanel touch display with WEBSeason®
Remote control: via computer, smartphone, or tablet
Interfaces: Ethernet, USB, and digital I/O
Power connection: 3/N/PE AC 400 V ±10 %, 50 Hz; actual design according to nameplate
Other connection options according to instructions: 380 V / 50 Hz or optionally 440 V / 60 Hz
Rated power: 31.9 kW
Rated current: 57 A
On-site protection: 63 A slow-blow fuse
Protection class, control cabinet and operating unit: IP23
Nsdoz Rwk Rspfx Ap Eolh
Cooling: water-cooled
Cooling water connections: Supply and return, each 1" internal thread
Cooling water temperature: +12 to +28 °C
Cooling water pressure: 2.5 to 6 bar
Differential pressure, cooling water circuit: over 2 bar
Cooling water consumption under full load with 18 °C inlet and 10 K heating: 2.9 m³/h
Cooling water consumption under full load with 28 °C inlet and 5 K heating: 5.8 m³/h
Maximum heat dissipation to the cooling water: 33.7 kW
Maximum heat dissipation to the installation room: 1 kW
Compressed air supply: 4 to 10 bar overpressure
Compressed air connection: quick-release coupling DN 7.2
Compressed air temperature: +2 to +50 °C
Condensate drain: hose connection Ø 8 mm
Sound pressure level: approx. 63 dB(A)
Permissible ambient temperature during operation: +10 to +35 °C
Permissible relative humidity at the installation location: max. 75 %
Refrigerant:
R449A 3.5 kg
R469A 2.5 kg
Shipping or freight transport possible.
Subject to changes, errors, and prior sale.
We will be happy to answer any further questions by telephone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Weiss ShockEvent D/210/a/V1
Type of equipment: Temperature-controlled shock testing chamber
Testing principle: Stationary test chamber with supply of warm, cold, and ambient air via flaps
Test chamber volume: approx. 210 liters
Usable test chamber width / height according to installation plan: 700 / 500 mm
Installation dimensions according to installation plan (W × D × H): approx. 1,480 × 1,670 × 1,967 mm, plus space for attachments
Weight: approx. 1,350 kg
Temperature range, warm chamber: +50 to +225 °C
Temperature range, test chamber, warm phase: +50 to +200 °C
Temperature range, test chamber, cold phase: −65 to 0 °C
Temperature range, cold chamber: −70 to 0 °C
Heating rate: 18 K/min, i.e. 18 °C
Cooling rate: 2 K/min, i.e. 2 °C
Temperature deviation over time: ±0.3 to ±0.5 K in steady state
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Heat compensation, cold phase: max. 6,000 W at −20 °C
Heat compensation, warm phase: 0 W
Maximum load, test chamber floor: 100 kg, evenly distributed
Maximum number of insert baskets: 7 pieces
Maximum load per insert basket: 7.5 kg
Maximum total load of insert baskets: 50 kg
Distance between insert baskets: 50 mm
Operation: WEBPanel touch display with WEBSeason®
Remote control: via computer, smartphone, or tablet
Interfaces: Ethernet, USB, and digital I/O
Power connection: 3/N/PE AC 400 V ±10 %, 50 Hz; actual design according to nameplate
Other connection options according to instructions: 380 V / 50 Hz or optionally 440 V / 60 Hz
Rated power: 31.9 kW
Rated current: 57 A
On-site protection: 63 A slow-blow fuse
Protection class, control cabinet and operating unit: IP23
Nsdoz Rwk Rspfx Ap Eolh
Cooling: water-cooled
Cooling water connections: Supply and return, each 1" internal thread
Cooling water temperature: +12 to +28 °C
Cooling water pressure: 2.5 to 6 bar
Differential pressure, cooling water circuit: over 2 bar
Cooling water consumption under full load with 18 °C inlet and 10 K heating: 2.9 m³/h
Cooling water consumption under full load with 28 °C inlet and 5 K heating: 5.8 m³/h
Maximum heat dissipation to the cooling water: 33.7 kW
Maximum heat dissipation to the installation room: 1 kW
Compressed air supply: 4 to 10 bar overpressure
Compressed air connection: quick-release coupling DN 7.2
Compressed air temperature: +2 to +50 °C
Condensate drain: hose connection Ø 8 mm
Sound pressure level: approx. 63 dB(A)
Permissible ambient temperature during operation: +10 to +35 °C
Permissible relative humidity at the installation location: max. 75 %
Refrigerant:
R449A 3.5 kg
R469A 2.5 kg
Shipping or freight transport possible.
Subject to changes, errors, and prior sale.
We will be happy to answer any further questions by telephone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
문의 보내기
전화기 & 팩스
+49 2861 ... 광고