Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 3.2 K/min
Cooling: 4.0 K/min
Heat compensation max. 2300 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Kfodpfx Ajrbigfod Hsa
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Weiss temperature test chamber With S!MCON / 32 control Water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 3.2 K/min
Cooling: 4.0 K/min
Heat compensation max. 2300 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Kfodpfx Ajrbigfod Hsa
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Borken
8,705 km
기후실
VötschVC³ 4060
VötschVC³ 4060
소형 광고
Moers
8,749 km
열 컨테이너 쿨박스
TKTC-780
TKTC-780
소형 광고
Borken
8,705 km
온도 캐비닛 335리터
WeissWT3-340/70 -72°C bis +180°C
WeissWT3-340/70 -72°C bis +180°C
소형 광고
Deinze
8,939 km
샷블라스팅 & 그릿블라스팅
LaborexI1650 P - sandblasting
LaborexI1650 P - sandblasting
소형 광고
Borken
8,705 km
온도 테스트 챔버 600리터
WeissWT3-600/40 -42°C bis +180°C
WeissWT3-600/40 -42°C bis +180°C
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다