Wilo DL-E 100/145-11/2-S1 CronoTwin 건식 런닝 듀얼 펌프 순환펌프Wilo
DL-E 100/145-11/2-S1
Wilo DL-E 100/145-11/2-S1 CronoTwin 건식 런닝 듀얼 펌프 순환펌프
Wilo
DL-E 100/145-11/2-S1
VB 부가세 별도
€6,638
상태
중고
위치
Borken 

기본 정보
- 제조업체:
- Wilo
- 상태:
- 양호 (중고)
가격 및 위치
VB 부가세 별도
€6,638
- 위치:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A18920911
- 참조 번호:
- 33806
- 업데이트:
- 마지막 업데이트: 07.10.2026
설명
Wilo DL-E 100/145-11/2-S1 Dry-running twin pump
Dry-running twin pump in an inline design for pipe installation or foundation mounting with an integrated frequency converter for electronic control, including constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-running twin pump in an inline design with flange connection and automatic power adjustment.
Application
Pumping of heating water (according to VDI 2035), cold water, and water-glycol mixtures without abrasive substances in heating, cold water, and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Controller operation (n=constant)
Manual operating mode
Setting of the differential pressure setpoint
Setting of the speed (manual operating mode)
Setting of the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Dodpfx Apewbqrtocecn
Fault acknowledgment
External control functions
Control input "Priority OFF"
Control input "External pump switchover" (only effective in twin pump operation)
Analog input 0-10 V, 0-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal from the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal from the pressure sensor
Alarm and display functions
Collective fault message SSM
Collective operating message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated tripping electronics
Access restriction
Twin pump management (twin pump or 2 x single pump)
Main/reserve operation (automatic fault switchover)
Main/reserve operation, pump switchover after 24 hours
Addition operation
Addition operation (efficiency-optimized peak load switching on and off)
Your advantages
Energy saving through integrated electronic power adjustment
Easy operation thanks to Green Button technology and display
Various operating modes: main/reserve operation and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (FMP) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Motor rated power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Immunity to interference EN 61800-3
Insulation class: F
Motor protection class: IP55
Motor protection: FMP integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: €29,006.25
More new and used items can be found in our shop!
International shipping costs on request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Dry-running twin pump in an inline design for pipe installation or foundation mounting with an integrated frequency converter for electronic control, including constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-running twin pump in an inline design with flange connection and automatic power adjustment.
Application
Pumping of heating water (according to VDI 2035), cold water, and water-glycol mixtures without abrasive substances in heating, cold water, and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Controller operation (n=constant)
Manual operating mode
Setting of the differential pressure setpoint
Setting of the speed (manual operating mode)
Setting of the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Dodpfx Apewbqrtocecn
Fault acknowledgment
External control functions
Control input "Priority OFF"
Control input "External pump switchover" (only effective in twin pump operation)
Analog input 0-10 V, 0-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal from the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal from the pressure sensor
Alarm and display functions
Collective fault message SSM
Collective operating message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated tripping electronics
Access restriction
Twin pump management (twin pump or 2 x single pump)
Main/reserve operation (automatic fault switchover)
Main/reserve operation, pump switchover after 24 hours
Addition operation
Addition operation (efficiency-optimized peak load switching on and off)
Your advantages
Energy saving through integrated electronic power adjustment
Easy operation thanks to Green Button technology and display
Various operating modes: main/reserve operation and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (FMP) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Motor rated power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Immunity to interference EN 61800-3
Insulation class: F
Motor protection class: IP55
Motor protection: FMP integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: €29,006.25
More new and used items can be found in our shop!
International shipping costs on request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
최종 온라인: 지난주
등록일: 2008
541 온라인 광고
문의 보내기
전화기 & 팩스
+49 2862 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Framrach
8,664 km
컨베이어
ASCOCB 3000 - 2023
ASCOCB 3000 - 2023
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Frankenberg/Sa.
8,462 km
이타폼 G 150-250 펌프
KSBETANORM G 150-250 G10
KSBETANORM G 150-250 G10
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Thisted
8,227 km
그룬포스 펌프
GrundfosCR 8-30
GrundfosCR 8-30
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Leipzig
8,462 km
Linearmotor
Leomotor A/SKC 218B159 - LM 2000 - 12630
Leomotor A/SKC 218B159 - LM 2000 - 12630
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Luckenwalde
8,370 km
바 이송 컨베이어 시스템
PROTONBar Transferred Conveyor
PROTONBar Transferred Conveyor
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Nordhorn
8,648 km
컨베이어 벨트
Caljan
Caljan
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Topole
8,032 km
롤러 컨베이어
RegaluxEPRIS760-10000
RegaluxEPRIS760-10000
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Detmold
8,603 km
가위 리프트 테이블
WTT2600 x 800 mm
WTT2600 x 800 mm
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Topole
8,032 km
상승 벨트 컨베이어
VanderlandeZ-Förderer
VanderlandeZ-Förderer
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Piskorzów
8,238 km
전동기 210Kw
LoherANSA 315LB-04C
LoherANSA 315LB-04C
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다