Wilo DL-E 100/145-11/2-S1 Dry-running Twin Pump
Dry-running twin pump in an inline design for pipe installation or base mounting, with an integrated frequency converter for electronic control, among other things, for constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-running twin pump in an inline design with flange connection and automatic performance adjustment.
Application
Pumping of heating water (according to VDI 2035), cold water, and water-glycol mixtures without abrasive substances in heating, cold water, and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Controller operation (n=constant)
Manual control mode
Setting of the differential pressure setpoint
Setting of the speed (manual control mode)
Setting of the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Error acknowledgment
External control functions
Control input "Priority OFF"
Control input "External pump switchover" (only effective in twin pump operation)
Analog input 0-10 V, 0–20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 2–10 V, 4–20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 0–10 V for actual value signal of the pressure sensor
Analog input 2–10 V, 0-20 mA, 4–20 mA for actual value signal of the pressure sensor
Alarm and display functions
Ndedpewbqrtsfx Accsd
Collective fault message SSM
Collective operating message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated tripping electronics
Access lock
Twin pump management (twin pump or 2 x single pump)
Main/standby operation (automatic fault switchover)
Main/standby operation, pump switchover after 24 hours
Addition operation
Addition operation (efficiency-optimized peak load switching on/off)
Your advantages
Energy savings thanks to integrated electronic performance adjustment
Easy operation thanks to Green Button technology and display
Various operating modes: main/standby operation and parallel operation
Configurable error behavior tailored to heating and air conditioning applications
Integrated full motor protection (FMP) with tripping electronics
Drive
Power connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power input P1 max: 13000 W
Motor rated power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Immunity to interference EN 61800-3
Insulation class: F
Motor protection: IP55
Motor protection: FMP integrated
Installation dimensions
Installation length L0: 500 mm
Suction-side pipe connection DNs: DN 100
Discharge-side pipe connection DNd: DN 100
RRP: 29,006.25 €
More items, new and used - find them in our shop!
International shipping costs on request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Dry-running twin pump in an inline design for pipe installation or base mounting, with an integrated frequency converter for electronic control, among other things, for constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-running twin pump in an inline design with flange connection and automatic performance adjustment.
Application
Pumping of heating water (according to VDI 2035), cold water, and water-glycol mixtures without abrasive substances in heating, cold water, and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Controller operation (n=constant)
Manual control mode
Setting of the differential pressure setpoint
Setting of the speed (manual control mode)
Setting of the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Error acknowledgment
External control functions
Control input "Priority OFF"
Control input "External pump switchover" (only effective in twin pump operation)
Analog input 0-10 V, 0–20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 2–10 V, 4–20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 0–10 V for actual value signal of the pressure sensor
Analog input 2–10 V, 0-20 mA, 4–20 mA for actual value signal of the pressure sensor
Alarm and display functions
Ndedpewbqrtsfx Accsd
Collective fault message SSM
Collective operating message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated tripping electronics
Access lock
Twin pump management (twin pump or 2 x single pump)
Main/standby operation (automatic fault switchover)
Main/standby operation, pump switchover after 24 hours
Addition operation
Addition operation (efficiency-optimized peak load switching on/off)
Your advantages
Energy savings thanks to integrated electronic performance adjustment
Easy operation thanks to Green Button technology and display
Various operating modes: main/standby operation and parallel operation
Configurable error behavior tailored to heating and air conditioning applications
Integrated full motor protection (FMP) with tripping electronics
Drive
Power connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power input P1 max: 13000 W
Motor rated power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Immunity to interference EN 61800-3
Insulation class: F
Motor protection: IP55
Motor protection: FMP integrated
Installation dimensions
Installation length L0: 500 mm
Suction-side pipe connection DNs: DN 100
Discharge-side pipe connection DNd: DN 100
RRP: 29,006.25 €
More items, new and used - find them in our shop!
International shipping costs on request!
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
최근 온라인: 오늘
등록일: 2008
536 온라인 광고
문의 보내기
전화기 & 팩스
+49 2862 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Framrach
8,664 km
컨베이어
ASCOCB 3000 - 2023
ASCOCB 3000 - 2023
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Frankenberg/Sa.
8,462 km
이타폼 G 150-250 펌프
KSBETANORM G 150-250 G10
KSBETANORM G 150-250 G10
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Thisted
8,227 km
그룬포스 펌프
GrundfosCR 8-30
GrundfosCR 8-30
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Luckenwalde
8,370 km
바 이송 컨베이어 시스템
PROTONBar Transferred Conveyor
PROTONBar Transferred Conveyor
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Leipzig
8,462 km
Linearmotor
Leomotor A/SKC 218B159 - LM 2000 - 12630
Leomotor A/SKC 218B159 - LM 2000 - 12630
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Nordhorn
8,648 km
컨베이어 벨트
Caljan
Caljan
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Topole
8,032 km
롤러 컨베이어
RegaluxEPRIS760-10000
RegaluxEPRIS760-10000
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Freiberg am Neckar
8,812 km
전기 모터
Expert Tünkers mit SEW MotorED 920/0178/2
Expert Tünkers mit SEW MotorED 920/0178/2
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Wiehl
8,740 km
강철 경첩이 있는 컨베이어 벨트
HSD FördertechnikSF 220
HSD FördertechnikSF 220
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Topole
8,032 km
상승 벨트 컨베이어
VanderlandeZ-Förderer
VanderlandeZ-Förderer
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다