Zwick Roell HIT5P Plus 진자 충격 시험기Zwick Roell Pendelschlagwerk
HIT5P Plus inkl. TestXpert III
Zwick Roell HIT5P Plus 진자 충격 시험기
Zwick Roell Pendelschlagwerk
HIT5P Plus inkl. TestXpert III
제조 연도
2019
상태
중고
위치
Borken 

사진은 보여줍니다
지도 표시
기계 정보
- 제조 연도:
- 2019
- 상태:
- 매우 좋음 (중고)
- 기능성:
- 완전히 작동합니다
가격 및 위치
- 위치:
- Mollenwieske 4a, 46325 Borken, Deutschland

전화하기
제안 세부 정보
- 광고 ID:
- A19716451
- 업데이트:
- 마지막 업데이트: 13.08.2025
설명
Zwick Roell Pendulum Impact Testing Machine HIT5P Plus incl. TestXpert III software and 2 Charpy pendulums
Year of Manufacture: 2019
Dossier number: DO733812
Safety guard, fixed left side
• 010924
TestXpert III Software
TestXpert III Basic Program 1035123
TestXpert III Standard Test Program 1035790
Manual
Charpy Pendulum 1J BPI-ACPECHI.112
Gsdpow H Andofx Adkobw
Charpy Pendulum 5J BPI-ACPECHI.115
Performed according to Charpy ISO 179-1:2000 + Amend. 1:2005 German Version EN ISO 179-1:2000 + A1_2005
Dimensions: 680 x 658 x 404 mm (without guard)
Maximum working capacity: 5 J
Dimensions (W x H x D): 680 x 658 x 404 mm (without guard)
Weight (without fixtures) approx. 75 kg
Electrical connection: 100 to 240 V, 50/60 Hz, 70 W
Interfaces: RS232, USB
Angular resolution: 0.018°
Test results,
numerical
Impact energy [%]
Impact energy [J; ft lbf]
Impact toughness [kJ/m²]
Control function: Pendulum vertical position
Oscillation duration
Pendulum vertical position
Oscillation period
Correction function: friction correction
Impact tensile test:
Air and bearing friction, kinetic yoke energy
3.1 Charpy Testing
The Charpy blocks consist of a solid cast base. Test-specific parts, such as anvils and supports, are selected according to the specimen spectrum.
The anvils, which through surface roughness and radius can significantly affect test results, are fully precision CNC-manufactured and 100% measured. Single-piece anvils, which often lack sufficient dimensional accuracy, are not offered by ZwickRoell. During installation, the spatial position of the anvils relative to the pendulum hammer is ensured by an optional gauge.
Anvils are subject to higher wear than supports, but two-piece anvils can be economically replaced independently of other accessories. Quick-change adapter plates allow adjustment of the impact point to the specimen width (impact direction). Adaptation to specimen thickness (vertical direction) is achieved by appropriately dimensioned supports, which are accurately fitted using locating pins.
Optional accessories for the testing frame include a pivoting safety shield and alignment units, which position the specimen either at the notch or at one end face aligned to the impact center.
Advantages:
• Rapid block change
• Precision manufacturing and documented 100% dimensional accuracy control of the anvils
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Year of Manufacture: 2019
Dossier number: DO733812
Safety guard, fixed left side
• 010924
TestXpert III Software
TestXpert III Basic Program 1035123
TestXpert III Standard Test Program 1035790
Manual
Charpy Pendulum 1J BPI-ACPECHI.112
Gsdpow H Andofx Adkobw
Charpy Pendulum 5J BPI-ACPECHI.115
Performed according to Charpy ISO 179-1:2000 + Amend. 1:2005 German Version EN ISO 179-1:2000 + A1_2005
Dimensions: 680 x 658 x 404 mm (without guard)
Maximum working capacity: 5 J
Dimensions (W x H x D): 680 x 658 x 404 mm (without guard)
Weight (without fixtures) approx. 75 kg
Electrical connection: 100 to 240 V, 50/60 Hz, 70 W
Interfaces: RS232, USB
Angular resolution: 0.018°
Test results,
numerical
Impact energy [%]
Impact energy [J; ft lbf]
Impact toughness [kJ/m²]
Control function: Pendulum vertical position
Oscillation duration
Pendulum vertical position
Oscillation period
Correction function: friction correction
Impact tensile test:
Air and bearing friction, kinetic yoke energy
3.1 Charpy Testing
The Charpy blocks consist of a solid cast base. Test-specific parts, such as anvils and supports, are selected according to the specimen spectrum.
The anvils, which through surface roughness and radius can significantly affect test results, are fully precision CNC-manufactured and 100% measured. Single-piece anvils, which often lack sufficient dimensional accuracy, are not offered by ZwickRoell. During installation, the spatial position of the anvils relative to the pendulum hammer is ensured by an optional gauge.
Anvils are subject to higher wear than supports, but two-piece anvils can be economically replaced independently of other accessories. Quick-change adapter plates allow adjustment of the impact point to the specimen width (impact direction). Adaptation to specimen thickness (vertical direction) is achieved by appropriately dimensioned supports, which are accurately fitted using locating pins.
Optional accessories for the testing frame include a pivoting safety shield and alignment units, which position the specimen either at the notch or at one end face aligned to the impact center.
Advantages:
• Rapid block change
• Precision manufacturing and documented 100% dimensional accuracy control of the anvils