CTS
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Itsdpeva Hi Hofx Ad Her
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Itsdpeva Hi Hofx Ad Her
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
이 광고들도 당신에게 관심이 있을 수 있습니다.
소형 광고
Borken
8,705 km
온도 테스트 챔버 1000리터
CTST-55/1000 Li -50°C bis 100°C
CTST-55/1000 Li -50°C bis 100°C
소형 광고
Bovenden
8,573 km
기타
AtlasMobilbagger AB 1302 D
AtlasMobilbagger AB 1302 D
소형 광고
Borken
8,705 km
교대 기후 캐비닛
BinderMKF 720 E1 / E1.1
BinderMKF 720 E1 / E1.1
소형 광고
Lublin
7,908 km
냉각기/히트 펌프
Used Watercooled Chiller DaikinEWHQ120G 95/130 kW 2019 yom
Used Watercooled Chiller DaikinEWHQ120G 95/130 kW 2019 yom
소형 광고
Burgoberbach
8,717 km
사출 성형기
Arburg270U 400-60 199103
Arburg270U 400-60 199103
소형 광고
Borken
8,705 km
습도가 있는 기후 테스트 챔버
VötschVC³ 4100 990 Liter -42°C bis +180°C
VötschVC³ 4100 990 Liter -42°C bis +180°C
소형 광고
Lublin
7,912 km
냉각기
Used Watercooled Chiller EF COOLINGEVO 90 WKL770FC 88 kW 2019 yom
Used Watercooled Chiller EF COOLINGEVO 90 WKL770FC 88 kW 2019 yom
소형 광고
Odder
8,235 km
터미널 트랙터
KalmarTRL618I 4X4
KalmarTRL618I 4X4
소형 광고
Borken
8,705 km
워크인 기후실
WeissWK 27'/50-150 -50°C bis 150°C
WeissWK 27'/50-150 -50°C bis 150°C
소형 광고
Borken
8,705 km
온도 테스트 캐비닛
VötschVTS³ 7018-5
VötschVTS³ 7018-5
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다