요구르트, 페이스트, 펄프 및 기타 점성 제품용 튜브 인 튜브(이중관) 열교환기DMUK
13 Meters of Tube in Tube
요구르트, 페이스트, 펄프 및 기타 점성 제품용 튜브 인 튜브(이중관) 열교환기
DMUK
13 Meters of Tube in Tube
제조 연도
2009
상태
중고
위치
Derby 

기본 정보
가격 및 위치
- 위치:
- Derby, UK

전화하기
제안 세부 정보
- 광고 ID:
- A22954601
- 참조 번호:
- 808
- 업데이트:
- 마지막 업데이트: 13.10.2026
설명
AI Overview
A 13-meter tube-in-tube heat exchanger paired with a mono (progressive cavity) pump is a heavy-duty industrial setup designed for continuous heating or cooling of high-viscosity, abrasive, or fiber- and particulate-laden fluids (such as wastewater sludge, digestate, food purees, pulps, or industrial effluents). [1, 2, 3]
Core System Components & Description
Tube-in-Tube (Double-Pipe) Heat Exchanger (13 Meters):
Design: Consists of a concentric layout where a smaller inner tube (often corrugated to boost turbulence and heat transfer) is nested inside a larger outer shell tube.
Flow Configuration: The process fluid flows counter-currently through the inner tube, while the service/heating/cooling medium flows through the annular space between the inner and outer tubes.
Length & Scale: A 13-meter run (frequently modular or multi-pass/series-connected units mounted on a skid frame) provides an extended thermal exchange surface area suited for duty points requiring significant temperature delta (Δ T) without clogging.
Handling Solids: Ideal for fluids containing suspended solids, large particles, or fibers up to tens of millimeters that would choke standard plate heat exchangers. [1, 2, 3, 4, 5, 6]
Mono Pump (Progressive Cavity Pump):
Bdodpfx Aajz Ruxljtei
Function: Acts as a positive-displacement feed pump that delivers a steady, controlled, low-shear flow rate of the product medium into the heat exchanger.
Why it fits: Progressive cavity ("mono") technology prevents pulsation and handles abrasive, thick, or high-viscosity slurries smoothly without damaging sensitive cell structures or choking under backpressure. [1]
Key Applications
Wastewater and sewage sludge heating or cooling.
Viscous food-industry processing (sauces, pulps, creams, purees).
Industrial effluent and dye-house waste heat recovery.
Continuous thermal treatment requiring plug-flow characteristics and easy Clean-in-Place (CIP) maintenance
Cooling: Yes
Heating: Yes
Temperatures: Depending on Connection
Feed Pump: Mono Pump for Viscous Products
CIP: This is cleaned through the CIP system
Tube in Tube Legth: 13 meters including bends
A 13-meter tube-in-tube heat exchanger paired with a mono (progressive cavity) pump is a heavy-duty industrial setup designed for continuous heating or cooling of high-viscosity, abrasive, or fiber- and particulate-laden fluids (such as wastewater sludge, digestate, food purees, pulps, or industrial effluents). [1, 2, 3]
Core System Components & Description
Tube-in-Tube (Double-Pipe) Heat Exchanger (13 Meters):
Design: Consists of a concentric layout where a smaller inner tube (often corrugated to boost turbulence and heat transfer) is nested inside a larger outer shell tube.
Flow Configuration: The process fluid flows counter-currently through the inner tube, while the service/heating/cooling medium flows through the annular space between the inner and outer tubes.
Length & Scale: A 13-meter run (frequently modular or multi-pass/series-connected units mounted on a skid frame) provides an extended thermal exchange surface area suited for duty points requiring significant temperature delta (Δ T) without clogging.
Handling Solids: Ideal for fluids containing suspended solids, large particles, or fibers up to tens of millimeters that would choke standard plate heat exchangers. [1, 2, 3, 4, 5, 6]
Mono Pump (Progressive Cavity Pump):
Bdodpfx Aajz Ruxljtei
Function: Acts as a positive-displacement feed pump that delivers a steady, controlled, low-shear flow rate of the product medium into the heat exchanger.
Why it fits: Progressive cavity ("mono") technology prevents pulsation and handles abrasive, thick, or high-viscosity slurries smoothly without damaging sensitive cell structures or choking under backpressure. [1]
Key Applications
Wastewater and sewage sludge heating or cooling.
Viscous food-industry processing (sauces, pulps, creams, purees).
Industrial effluent and dye-house waste heat recovery.
Continuous thermal treatment requiring plug-flow characteristics and easy Clean-in-Place (CIP) maintenance
Cooling: Yes
Heating: Yes
Temperatures: Depending on Connection
Feed Pump: Mono Pump for Viscous Products
CIP: This is cleaned through the CIP system
Tube in Tube Legth: 13 meters including bends
공급자
참고: 무료로 등록하거나 로그인하세요, 모든 정보를 확인할 수 있습니다.
등록일: 2017
26 온라인 광고
문의 보내기
전화기 & 팩스
+44 1332 ... 광고
이 광고들도 당신에게 관심이 있을 수 있습니다.
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Thisted
8,227 km
호모게나이저
APVRannie Blue Top
APVRannie Blue Top
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Lorquí
10,270 km
동질화 장치가 포함된 주스 혼합 라인
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Lorquí
10,270 km
BERTOLI H5 150 스테인리스 호모게나이저
BERTOLIH5 150
BERTOLIH5 150
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Janville
9,246 km
피스톤 호모게나이저
APV RannieRannie - R275 Q-70 5140 X
APV RannieRannie - R275 Q-70 5140 X
성공
귀하의 메시지가 전송되었습니다.
소형 광고
Lorquí
10,270 km
200g 브릭 무균 충전기
TETRA PAKTBA/19 200B
TETRA PAKTBA/19 200B
귀하의 광고가 성공적으로 삭제되었습니다
오류가 발생했습니다