기후 챔버 - 클린룸PK-Kältetechnik - Clean or Climate rooms
Climate - Clean room
기후 챔버 - 클린룸
PK-Kältetechnik - Clean or Climate rooms
Climate - Clean room
제조 연도
2018
상태
중고
위치
Maasmechelen 

사진은 보여줍니다
지도 표시
기계 정보
가격 및 위치
- 위치:
- Breitwatertraat 22, 3630 Maasmechelen, BE

전화하기
제안 세부 정보
- 광고 ID:
- A19631221
- 참조 번호:
- S-LTD-325
- 업데이트:
- 마지막 업데이트: 18.08.2025
설명
PK clima – Clean Rooms
We can offer three different cleanroom configurations. Please let us know your required size:
A x 150 m² (3 chambers)
B x 320 m² (7 chambers) – 112 m² + 55 m² + 34 m² + 38 m² + 40 m² + 25 m²
C x (please specify)
Item 1) Cleanroom Block 1 approx. 150 m²
Inlet with the following technical specifications:
- Cleanroom Class ISO6
- Lighting: 300 lux
- All doors equipped with electric locks
Manufacturer and model: MGB
- Clear room height: 2,500 mm throughout
On-site extraction system: 500–2,000 m³/h
Inlet slot: 1,800 x 50 mm
Outlet 1: 3,700 x 50 mm
Outlet slot: 1,800 x 50 mm
2 double doors
1 maintenance door
• DIG Cell: Solvent extraction via industrial exhaust fan
Manufacturer: Ghrd, with external drive motor and frequency converter
Approx. 5 g/m² solvent applied to the panel
Exhaust duct outlets 2 m above the cell
Roof penetrations and sealing to be provided by the customer
Negative pressure monitoring included
2 double doors
• T Cell: Extraction via industrial exhaust fan
Manufacturer: Ghrd, with external drive motor and frequency converter
Exhaust air combined with that of the DIG cell
Negative pressure monitoring to prevent solvent leakage to exterior
2 double doors
Comprising:
- Approx. 175 m² tongue-and-groove panel walls, RAL 9002, smooth finish, with eccentric fasteners
- Multiple window elements integrated into the panel walls as per specification
6 doors with windows (double-leaf, clear opening 1,800 x 2,000 mm)
1 operating room door (single-leaf, clear opening 2,000 x 2,200 mm)
6 electric door locks as described
22 filter fan units (1,140 x 1,140 mm each), with F7 pre-filter, H14 main filter, EC speed-controllable motor
Air volume: 2,350 m³/h
Nominal power: 350 W
Sound power: approx. 55 dB(A)
Approx. 40 lighting units with cover (no LED)
Approx. 200 m² cleanroom ceiling, make: O – metal ceiling
1 set of suspension structure for the metal ceiling, including maintenance grid for service and filter replacement from above
1 exhaust fan with ductwork
1 switch cabinet section for control
Additional option:
Item 3) Additional Air Conditioning for DIG Room
To achieve the specified room temperature and humidity, an additional air conditioning unit is required:
- Target room temperature: +20°C ±2K
- Target humidity: 60% ±10%
Bjdpfx Abjw Dddzemeww
- Control integrated into main control cabinet
이 광고는 자동으로 번역되었습니다. 번역 오류가 있을 수 있습니다.
We can offer three different cleanroom configurations. Please let us know your required size:
A x 150 m² (3 chambers)
B x 320 m² (7 chambers) – 112 m² + 55 m² + 34 m² + 38 m² + 40 m² + 25 m²
C x (please specify)
Item 1) Cleanroom Block 1 approx. 150 m²
Inlet with the following technical specifications:
- Cleanroom Class ISO6
- Lighting: 300 lux
- All doors equipped with electric locks
Manufacturer and model: MGB
- Clear room height: 2,500 mm throughout
On-site extraction system: 500–2,000 m³/h
Inlet slot: 1,800 x 50 mm
Outlet 1: 3,700 x 50 mm
Outlet slot: 1,800 x 50 mm
2 double doors
1 maintenance door
• DIG Cell: Solvent extraction via industrial exhaust fan
Manufacturer: Ghrd, with external drive motor and frequency converter
Approx. 5 g/m² solvent applied to the panel
Exhaust duct outlets 2 m above the cell
Roof penetrations and sealing to be provided by the customer
Negative pressure monitoring included
2 double doors
• T Cell: Extraction via industrial exhaust fan
Manufacturer: Ghrd, with external drive motor and frequency converter
Exhaust air combined with that of the DIG cell
Negative pressure monitoring to prevent solvent leakage to exterior
2 double doors
Comprising:
- Approx. 175 m² tongue-and-groove panel walls, RAL 9002, smooth finish, with eccentric fasteners
- Multiple window elements integrated into the panel walls as per specification
6 doors with windows (double-leaf, clear opening 1,800 x 2,000 mm)
1 operating room door (single-leaf, clear opening 2,000 x 2,200 mm)
6 electric door locks as described
22 filter fan units (1,140 x 1,140 mm each), with F7 pre-filter, H14 main filter, EC speed-controllable motor
Air volume: 2,350 m³/h
Nominal power: 350 W
Sound power: approx. 55 dB(A)
Approx. 40 lighting units with cover (no LED)
Approx. 200 m² cleanroom ceiling, make: O – metal ceiling
1 set of suspension structure for the metal ceiling, including maintenance grid for service and filter replacement from above
1 exhaust fan with ductwork
1 switch cabinet section for control
Additional option:
Item 3) Additional Air Conditioning for DIG Room
To achieve the specified room temperature and humidity, an additional air conditioning unit is required:
- Target room temperature: +20°C ±2K
- Target humidity: 60% ±10%
Bjdpfx Abjw Dddzemeww
- Control integrated into main control cabinet